9 Positioning Control
9.8 Multi-Speed Operation
172
FX
3U
-20SSC-H Positioning Block User's Manual
BFM Number
Data type
X-axis
Y-axis
m code OFF
Operation command 1
BFM #518 b11
BFM #618 b11
Control data
Change command in operation
disabled
Operation command 1
BFM #518 b12
BFM #618 b12
Control data
Speed change command in
positioning operation
Operation command 1
BFM #518 b13
BFM #618 b13
Control data
Remaining distance operation
cancel command
Operation command 2
BFM #519 b0
BFM #619 b0
Control data
Acceleration/deceleration time
change command
(Ver. 1.30 or later)
Operation command 2
BFM #519 b5
BFM #619 b5
Control data
Ring operation rotation direction for absolute address
(Ver. 1.10 or later)
BFM #530
BFM #630
Control data
X-START(Input terminal)
-
-
Input terminal
Y-START(Input terminal)
-
-
Input terminal
m code number
BFM #9
BFM #109
Monitor data
Number of the table in operation
BFM #16
BFM #116
Monitor data
Positioning completion
Status information
BFM #28 b6
BFM #128 b6
Monitor data
READY/BUSY
Status information
BFM #28 b0
BFM #128 b0
Monitor data
Standby for remaining travel
distance at stop
Status information
BFM #28 b7
BFM #128 b7
Monitor data
During table operation
execution
Status information
BFM #28 b15
BFM #128 b15
Monitor data
Received target address (Ver. 1.20 or later)
BFM #25,#24
BFM #125,#124
Monitor data
Received target speed (Ver. 1.20 or later)
BFM #27,#26
BFM #127,#126
Monitor data
Current address (user)
BFM #1,#0
BFM #101,#100
Monitor data
Current address (pulse)
BFM #3,#2
BFM #103,#102
Monitor data
Real current address (user) (Ver. 1.20 or later)
BFM #21,#20
BFM #121,#120
Monitor data
Real current address (pulse) (Ver. 1.20 or later)
BFM #23,#22
BFM #123,#122
Monitor data
Operation speed present value
BFM #11,#10
BFM #111,#110
Monitor data
System of units (user unit)
Operation parameter 1
BFM #14000 b1,b0
BFM #14200 b1,b0
Positioning parameters
Unit of measurement for the
user units
Operation parameter 1
BFM #14000 b3,b2
BFM #14200 b3,b2
Positioning parameters
Position data magnification
Operation parameter 1
BFM #14000 b5,b4
BFM #14200 b5,b4
Positioning parameters
Acceleration/deceleration
mode
Operation parameter 1
BFM #14000 b11
BFM #14200 b11
Positioning parameters
STOP mode
Operation parameter 1
BFM #14000 b15
BFM #14200 b15
Positioning parameters
Servo end check enabled/
disabled
Operation parameter 2
BFM #14002 b0
BFM #14202 b0
Positioning parameters
Servo ready check enabled/
disabled
Operation parameter 2
BFM #14002 b1
BFM #14202 b1
Positioning parameters
Ring counter setting
(Ver. 1.10 or later)
Operation parameter 2
BFM #14002 b3
BFM #14202 b3
Positioning parameters
Pulse rate
BFM #14005,#14004 BFM #14205,#14204 Positioning parameters
Feed rate
BFM #14007,#14006 BFM #14207,#14206 Positioning parameters
Maximum speed
BFM #14009,#14008 BFM #14209,#14208 Positioning parameters
Acceleration time
BFM #14018
BFM #14218
Positioning parameters
Deceleration time
BFM #14020
BFM #14220
Positioning parameters
Servo end evaluation time
BFM #14032
BFM #14232
Positioning parameters
Ring counter upper limit value (Ver. 1.10 or later)
BFM #14101,#14100 BFM #14301,#14300 Positioning parameters
Positioning completion signal output waiting time
(Ver. 1.20 or later)
BFM #14106
BFM #14306
Positioning parameters
Acceleration time 2 (Ver. 1.30 or later)
BFM #14108
BFM #14308
Positioning parameters
Deceleration time 2 (Ver. 1.30 or later)
BFM #14110
BFM #14310
Positioning parameters