7.4 Handling the STOP command
To cancel the remaining travel distance operation in the remaining
travel distance operation mode
When "remaining travel distance operation cancel command" is turned ON in standby status, the operation
for the remaining travel distance is cancelled and the positioning operation terminates.
3. Wiring the stop switch
Connect the stop switch to the input terminal of the PLC.
For details of the PLC wiring method, refer to the following manual according to the PLC being used.
→
Refer to the FX
3U
Hardware Edition
→
Refer to the FX
3UC
Hardware Edition
4. STOP command
Operate the PLC's STOP switch together with the 20SSC-H STOP command.
BFM Number
Data type
X-axis
Y-axis
START command
Operation command 1 BFM #518 b9
BFM #618 b9
Control data
STOP command
Operation command 1 BFM #518 b1
BFM #618 b1
Control data
Standby for remaining travel
distance at stop
Status information
BFM #28 b7
BFM #128 b7
Monitor data
Remaining distance operation
cancel command
Operation command 2 BFM #519 b0
BFM #619 b0
Control data
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Speed
Remaining travel distance operation
(Canceled remaining travel distance)
Time
START command
STOP command
Standby for remaining travel distance after stopped
Remaining travel distance operation cancel command