11 Buffer Memory (Parameters & Monitored Data)
11.2 Servo Parameters
220
FX
3U
-20SSC-H Positioning Block User's Manual
BFM
#15036
BFM
#15236
PB18
Low pass filter setting
Set the low pass filter.
Setting range: 100 to 18000 rad/s
K3141
BFM
#15037
BFM
#15237
PB19
Vibration
suppression control
vibration frequency
setting
Set the vibration frequency for vibration suppression control to suppress
low-frequency machine vibration, such as enclosure vibration.
Setting range: 1 to 1000 (
×
0.1 Hz)
K1000
BFM
#15038
BFM
#15238
PB20
Vibration
suppression control
resonance frequency
setting
Set the resonance frequency for vibration suppression control to
suppress low-frequency machine vibration, such as enclosure vibration.
Setting range: 1 to 1000 (
×
0.1 Hz)
K1000
BFM
#15041
BFM
#15241
PB23
Low pass filter
selection
Select the procedure to set the low pass filter.
0: Automatic setting
1: Manual setting (specify a number for the low pass filter setting)
H0000
BFM
#15042
BFM
#15242
PB24
Slight vibration
suppression control
selection
Select the slight vibration suppression control.
• Slight vibration suppression control selection
0: Disable
1: Enable
• PI-PID switch over selection
0: Enables PI control
3: Enables PID control all the time
H0000
BFM
#15044
BFM
#15244
PB26
Gain changing
selection
Select the gain changing selections/conditions.
• Gain changing selection
0: Disable
1: Settings designated by a gain change command take effect
2: Set command frequency as a trigger to change gain
3: Set droop pulses as a trigger to change gain
4: Set servo motor speed as a trigger to change gain
• Gain changing condition
0: Valid when a value is bigger than the set value
1: Valid when a value is smaller than the set value
H0000
BFM
#15045
BFM
#15245
PB27
Gain changing
condition
Set the value for gain changing condition.
Setting range: 0 to 9999 (kpps, PLS, r/min)
K10
BFM
#15046
BFM
#15246
PB28
Gain changing time
constant
Set the time constant for changing gain.
Setting range: 0 to 100 ms
K1
BFM
#15047
BFM
#15247
PB29
Gain changing
Ratio of load inertia
moment to servo
motor inertia moment
Set the ratio of load inertia moment to servo motor inertia moment when
gain changing is valid.
Setting range: 0 to 3000 (
×
0.1 times)
K70
BFM
#15048
BFM
#15248
PB30
Gain changing
Position loop gain
Set the position loop gain when the gain changing is valid.
Setting range: 1 to 2000 rad/s
K37
BFM
#15049
BFM
#15249
PB31
Gain changing
Speed loop gain
Set the speed loop gain when the gain changing is valid.
Setting range: 20 to 50000 rad/s
K823
BFM
#15050
BFM
#15250
PB32
Gain changing
Speed integral
compensation
Set the speed integral compensation when the gain changing is valid.
Setting range: 1 to 50000 (
×
0.1 ms)
K337
BFM
#15051
BFM
#15251
PB33
Gain changing
Vibration
suppression control
vibration frequency
setting
Set the vibration frequency for vibration suppression control when the
gain changing is valid.
Setting range: 1 to 1000 (
×
0.1 Hz)
K1000
BFM Number
Servo
Amplifier
Parameter No.
Name
Description
Default
X-axis
Y-axis
Low-pass filter (LPF) selection
0
0
0
Micro-vibration suppression
control selection
0
0
PI-PID switch over selection
Gain changing selection
0
0
Gain changing condition