9 Positioning Control
9.5 Interrupt 2-speed Constant Quantity Feed
163
FX
3U
-20SSC-H Positioning Block User's Manual
1
Int
roduct
ion
2
Sy
stem
conf
igur
ati
on
3
Exam
ple
C
onnect
ion
4
Ins
tall
a
tion
5
Wi
rin
g
6
Me
m
o
ry
confi
gur
at
ion
and da
ta
7
Befor
e
star
ting
positi
oning
contr
o
l
8
M
anual c
ont
ro
l
9
Posit
ioni
ng
C
ont
rol
10
Table O
per
at
ion
9.5
Interrupt 2-speed Constant Quantity Feed
→
For details on the operation speed change and target address change, refer to Section 7.6
→
For details on the torque limit, refer to Subsection 7.9.3
→
For details on the STOP command, refer to Section 7.4
→
For setting of ring operation in the current address, refer to Section 7.8
→
For details on the table operation, refer to Chapter 10
1. Operation
1) Set the operation speed 1, operation speed 2, and target address 1.
2) Select Interrupt 2-speed constant quantity feed from the operation patterns and activate the START
command to start the Interrupt 2-speed constant quantity feed (above figure).
(The positioning completion signal is turned OFF.)
3) At interrupt input (INT0) ON, the work piece starts accelerating/decelerating to operation speed 2.
In the 20SSC-H Ver. 1.30 or later, the current address when an interrupt input (INT0) occurs is stored in
the "current address when an interrupt occurs (INT0)."
4) At interrupt input (INT1) ON, the work piece moves at operation speed 2 to target address 1, and the
operation ends, turning ON the positioning completion signal.
In a 20SSC-H Ver. 1.30 or later, the current address when an interrupt input (INT1) occurs is stored in the
"current address when an interrupt occurs (INT1)."
→
For the parameters, control data and monitor data, refer to Chapter 11
BFM Number
Data type
X-axis
Y-axis
Target address 1
BFM #501,#500
BFM #601,#600
Control data
Operation speed 1
BFM #503,#502
BFM #603,#602
Control data
Operation speed 2
BFM #507,#506
BFM #607,#606
Control data
Interrupt 2-speed constant
quantity feed
Operation pattern selection BFM #520 b3
BFM #620 b3
Control data
STOP command
Operation command 1
BFM #518 b1
BFM #618 b1
Control data
START command
Operation command 1
BFM #518 b9
BFM #618 b9
Control data
Simultaneous START flag
Operation command 1
BFM #518 b10
Control data
Change command in operation
disabled
Operation command 1
BFM #518 b12
BFM #618 b12
Control data
Speed change command in
positioning operation
Operation command 1
BFM #518 b13
BFM #618 b13
Control data
Target position change
command in positioning
operation
Operation command 1
BFM #518 b14
BFM #618 b14
Control data
Remaining distance operation
cancel command
Operation command 2
BFM #519 b0
BFM #619 b0
Control data
Maximum
speed
Operation
speed 1
ON
ON
ON
OFF
OFF
OFF
Deceleration
time
Time
Acceleration
time
START command
Target address 1
2)
3)
4)
Operation speed 2
Interrupt input (INT0)
Interrupt input (INT1)
OFF
ON
Positioning
completion
ON
Speed