7 Before Starting Positioning Operation
132
FX
3U
-20SSC-H Positioning Block User's Manual
7.11 Cautions for Positioning Operation
7.11.4
Cautions on continuous pass operation
When the following interpolation operation exists in continuous pass operation, the system does not perform
continuous pass operation.
1) Interpolation operation conditions which disables continuous pass operation
a) Interpolation operation in which the m code is set in After mode
b) Interpolation operation in which the travel time is 50 ms or less
c) Interpolation operation in which the travel time is "Interpolation time constant 2" or less
2) System operation when continuous pass operation is disabled
*1.
When setting the m code in With mode in a 20SSC-H earlier than Ver.1.30, the system waits for the m
code OFF command, the m code OFF command is needed for the system operation to transition to
the next table.
Condition
Operation
Interpolation operation in which the m code is set in
After mode
The system waits for the m code OFF command.
When the m code OFF command is set to ON, the system operation will
transition to the next table.
Interpolation operation in which the travel time is 50
ms or less
The system does not perform continuous pass operation (in which
inflection points make a smooth curve), but the system operation will
transition to the next table when positioning is completed. (Refer to the
following figure.)
Interpolation operation in which the travel time is
"Interpolation time constant 2" or less
"m" code number -1
Time
Speed
Y-axis
X-axis
m code in With mode
m code in With mode
Start
*1
*1
10001
10002
10003