7 Before Starting Positioning Operation
62
FX
3U
-20SSC-H Positioning Block User's Manual
7.1 Note on Setting Parameters
From the previous page
Setting the positioning parameters (Y-axis).
T12
Sets the operation
parameter 2 (X-axis) in
unit No. 1.
K2000000
FNC 12
DMOV
K2000000
U1\G14008
FNC 12
DMOV
H8007
U1\G14002
FNC 12
MOV
K50000
U1\G14012
FNC 12
DMOV
Sets the maximum speed
(X-axis) in unit No. 1.
Sets the jog speed (X-axis)
in unit No. 1.
Setting the positioning parameters (X-axis).
K1000000
FNC 12
DMOV
U1\G14024
U1\G14026
SET
M393
Sets the zero return speed
(high speed) (X-axis) in
unit No. 1.
Sets the zero return speed
(creep) (X-axis) in unit
No. 1.
T12
Sets the operation
parameter 2 (Y-axis) in
unit No. 1.
K2000000
FNC 12
DMOV
K2000000
U1\G14208
FNC 12
DMOV
H8007
U1\G14202
FNC 12
MOV
K50000
U1\G14212
FNC 12
DMOV
Sets the maximum speed
(Y-axis) in unit No. 1.
Sets the jog speed (Y-axis)
in unit No. 1.
K1000000
FNC 12
DMOV
U1\G14224
U1\G14226
SET
M394
Sets the zero return speed
(high speed) (Y-axis) in
unit No. 1.
Sets the zero return speed
(creep) (Y-axis) in unit
No. 1.
To the next page
To the next page
T12
Setting the servo parameters except the servo series (X-axis).
H0001
U1\G15003
FNC 12
MOV
Sets the absolute position
detection system (X-axis) in
unit No. 1.
H0100
U1\G15004
FNC 12
MOV
Sets the function selection
A-1 (X-axis) in unit No. 1.
Sets the function selection
C-4 (X-axis) in unit No. 1.
K1
U1\G15080
FNC 12
MOV
T12
Setting the servo parameters except the servo series (Y-axis).
H0001
U1\G15203
FNC 12
MOV
Sets the absolute position
detection system (Y-axis) in
unit No. 1.
H0100
U1\G15204
FNC 12
MOV
Sets the function selection
A-1 (Y-axis) in unit No. 1.
Sets the function selection
C-4 (Y-axis) in unit No. 1.
K1
U1\G15280
FNC 12
MOV
From the previous page