7 Before Starting Positioning Operation
48
FX
3U
-20SSC-H Positioning Block User's Manual
7.1 Note on Setting Parameters
7.1.3
Initializing parameters [FX Configurator-FP]
This subsection explains how to initialize positioning parameters and servo parameters in the 20SSC-H using
FX Configurator-FP.
The initialization method is explained on the condition that a file is created in FX Configurator-FP.
→
For details of FX Configurator-FP operation procedures,
refer to the FX Configurator-FP OPERATION MANUAL
1
Setting the connection destination
Select [Online]
[Connection setup].
When the Connection setup dialog box appears, set each item, and then click the [OK] button.
2
Connecting a personal computer to the PLC main unit
→
For the connection route, refer to the FX Configurator-FP OPERATION MANUAL
3
Initializing the positioning parameters and servo parameters stored in the
buffer memory of the 20SSC-H
Select [Online]
[Initialize module].
When the initialize module dialog box appears, select data to be initialized, and then click the [OK]
button.
Caution
The X-axis and the Y-axis cannot be initialized if either the X-axis or the Y-axis is in a status disabling
initialization (i.e. either axis is executing a positioning operation).
Make sure to wait until both the X-axis and the Y-axis are in a status enabling initialization, and then initialize
parameters.