11 Buffer Memory (Parameters & Monitored Data)
11.1 Positioning Parameters
215
FX
3U
-20SSC-H Positioning Block User's Manual
11
Buffer
M
e
m
o
ry
12
Pr
ogr
am
Exam
ple
13
D
iagnostics
A
List
of
Par
a
m
e
ter
s and
Da
ta
B
V
e
rs
ion
Infor
m
at
ion
11.1.26 Deceleration time 2 [BFM #14110, BFM #14310]
This parameter sets the time for the operation speed to reach zero from the maximum speed.
The deceleration time except in sudden stop and interpolation operation consists of two types, "deceleration
time" and "deceleration time 2."
Use the acceleration/deceleration time change command in operation command 2 to select which type should
be used for actual positioning operation (Ver. 1.30 or later).
→
For the deceleration time, refer to Section 7.2
→
For setting of the deceleration time, refer to Subsection 11.1.9
→
For changeover of the acceleration/deceleration time, refer to Section 7.7
Note
• The set value smaller than "0 ms" is handled as "1 ms", and the set value larger than "5001 ms" is handled
as "5000 ms."
• When using approximate S-shaped acceleration/deceleration, set a value within the range from 64 to 5000
ms (not less than 64 ms).
BFM Number
Description
Default
X-axis
Y-axis
BFM #14110
BFM #14310
Setting range: 1 to 5000 ms
K200