![background image](http://html.mh-extra.com/html/mitsubishi-electric/mr-j4-100a-rj/mr-j4-100a-rj_instruction-manual_238540886.webp)
APPENDIX
App. - 71
(2) For control circuit power supply
When the wiring for the control circuit power supply (L11/L21) is thinner than that for the main circuit
power supply (L1/L2/L3/N-), install an overcurrent protection device (fuse, etc.) to protect the branch
circuit.
Servo amplifier
Fuse (Class T)
Fuse (Class K5)
Current [A]
Voltage DC [V]
Current [A]
Voltage DC [V]
MR-J4-10A-RJ
MR-J4-20A-RJ
MR-J4-40A-RJ
MR-J4-60A-RJ
MR-J4-70A-RJ
MR-J4-100A-RJ
MR-J4-200A-RJ
1 400 1 400
MR-J4-350A-RJ
MR-J4-500A-RJ
MR-J4-700A-RJ
MR-J4-11KA-RJ
MR-J4-15KA-RJ
MR-J4-22KA-RJ