APPENDIX
App. - 67
App. 13 When using the servo amplifier with the DC power supply input
POINT
The DC power supply input is available with MR-J4-_A-RJ servo amplifiers with
software version C2 or later.
When using the MR-J4-_A-RJ servo amplifier with the DC power supply input,
set [Pr. PC27] to "_ _ _ 1".
App. 13.1 Connection example
CAUTION
Ensure that polarity (+/-) is correct. Otherwise, a burst, damage, etc. may occur.
For the signal and wirings not given in this section, refer to section 3.1.1 to 3.1.3.
(1) MR-J4-10A-RJ to MR-J4-100A-RJ
ALM
DOCOM
CN1
(Note 2)
24 V DC (Note 6)
Malfunction
RA1
L1
L2
L3
L11
L21
MC
ON
MC
CN1
Forced stop 2
(Note 2)
EM2
CN8
(Note 4)
Main circuit power supply
MCCB
SK
(Note 9)
+
-
24 V DC (Note 6)
Servo-on
SON
DICOM
Malfunction
RA1
OFF
MC (Note 3)
24 V DC (Note 7, 8)
3-phase or 1-phase
200 V AC to 240 V AC
Servo amplifier
Emergency stop switch
(Note 1)
AC/DC
Converter
(283 V DC to
340 V DC)
(Note 5)
Short-circuit connector
(packed with the servo
amplifier)
Note 1. For the power supply specifications, refer to section 1.3.
2. This diagram shows sink I/O interface. For source I/O interface, refer to section 3.9.3.
3. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less. Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may
cause the forced stop deceleration to shift to the dynamic brake deceleration. When dynamic brake deceleration is not
required, delay the time to turn off the magnetic contactor.
4. Configure a circuit to turn off EM2 when the main circuit power is turned off to prevent an unexpected restart of the servo
amplifier.
5. When not using the STO function, attach the short-circuit connector came with a servo amplifier.
6. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they
can be configured by one.
7. Driving the on switch and off switch with the DC power supply meets IEC/EN 60204-1 requirements.
8. Do not use the 24 V DC interface power supply for the magnetic contactor DC power supply. Always use the power supply
designed exclusively for the magnetic contactor.
9. When wires used for L11 and L21 are thinner than wires used for L1 and L3, use a fuse. (Refer to app. 13.4.)
Содержание MR-J4-100A(-RJ)
Страница 19: ...10 MEMO ...
Страница 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Страница 83: ...2 INSTALLATION 2 8 MEMO ...
Страница 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 203: ...4 STARTUP 4 44 MEMO ...
Страница 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Страница 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 387: ...9 DIMENSIONS 9 22 MEMO ...
Страница 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Страница 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Страница 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Страница 856: ...APPENDIX App 41 ...
Страница 905: ...MEMO ...