3. SIGNALS AND WIRING
3 - 34
Device Symbol
Connector
pin No.
Function and application
I/O
division
Control
mode
P S T
Control switching
LOP
CN1-45 «Position/speed control change mode»
This is used to select the control mode in the position/speed control
switching mode.
DI-1 Refer
to
Function
and
application.
(Note) LOP
Control mode
0
Position
1
Speed
Note. 0: Off
1: On
«Speed/torque control change mode»
This is used to select the control mode in the speed/torque control
switching mode.
(Note) LOP
Control mode
0
Speed
1
Torque
Note. 0: Off
1: On
«Torque/position control change mode»
This is used to select the control mode in the torque/position control
switching mode.
(Note) LOP
Control mode
0
Torque
1
Position
Note. 0: Off
1: On
Second
acceleration/dece
leration selection
STAB2 The device allows selection of the acceleration/deceleration time constant
at servo motor rotation in the speed control mode or torque control mode.
The s-pattern acceleration time constant and deceleration time constant is
always uniform.
DI-1
(Note)
STAB2
Acceleration/deceleration time constant
0
Pr. PC01 Acceleration time constant
Pr. PC02 Deceleration time constant
1
Pr. PC30 Acceleration time constant 2
Pr. PC31 Deceleration time constant 2
Note. 0: Off
1: On
ABS transfer
mode
ABSM
CN1-17 This is an ABS transfer mode request device.
When "_ _ _ 1" is set in [Pr. PA03] and absolute position detection system
by DIO is selected, CN1-17 pin will become ABSM. (Refer to chapter 12.)
DI-1
ABS request
ABSR
CN1-18 This is an ABS request device.
When "_ _ _ 1" is set in [Pr. PA03] and absolute position detection system
by DIO is selected, CN1-18 pin will become ABSR. (Refer to chapter 12.)
DI-1
Fully closed loop
selection
CLD
This is used when the semi closed loop control/fully closed loop control
switching is enabled with [Pr. PE01].
Turn off CLD to select the semi closed loop control, and turn on CLD to
select the fully closed loop control.
This device is not available with MR-J4-03A6(-RJ) servo amplifiers.
DI-1
Motor-side/load-
side position
deviation counter
clear
MECR
Turn on MECR to clear the motor-side/load-side position deviation counter
to zero.
- It operates during the fully closed loop control.
- It does not affect the position control droop pulses.
- Turning on this device during the semi closed loop control does not affect
the operation.
- Turning on this device while the fully closed loop control error detection
function is disabled in [Pr. PE03] does not affect the operation.
This device is not available with MR-J4-03A6(-RJ) servo amplifiers.
DI-1
Содержание MR-J4-100A(-RJ)
Страница 19: ...10 MEMO ...
Страница 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Страница 83: ...2 INSTALLATION 2 8 MEMO ...
Страница 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 203: ...4 STARTUP 4 44 MEMO ...
Страница 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Страница 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 387: ...9 DIMENSIONS 9 22 MEMO ...
Страница 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Страница 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Страница 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Страница 856: ...APPENDIX App 41 ...
Страница 905: ...MEMO ...