14. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL)
14 - 17
14.4.2 Writing commands
(1) Status display (command [8] [1])
Command
Data No.
Description
Setting range
Frame length
[8] [1]
[0] [0]
Status display data deletion
1EA5
4
(2) Parameters (command [9] [4], [8] [5])
Command
Data No.
Description
Setting range
Frame length
[9] [4]
[0] [1] to [F] [F] Writing each parameter
Writes the values of the parameters in the parameter group specified
with the command [8] [5] + data No. [0] [0]. Before writing the values,
therefore, always specify the parameter group with the command [8]
[5] + data No. [0] [0].
The decimal equivalent of the data No. value (hexadecimal)
corresponds to the parameter No.
Depending on the
parameter
12
[8] [5]
[0] [0]
Parameter group writing
0000: Basic setting parameters ([Pr. PA_ _ ])
0001: Gain/filter parameters ([Pr. PB_ _ ])
0002: Extension setting parameters ([Pr. PC_ _ ])
0003: I/O setting parameters ([Pr. PD_ _ ])
0004: Extension setting 2 parameters ([Pr. PE_ _ ])
0005: Extension setting 3 parameters ([Pr. PF_ _ ])
000B: Linear servo motor/DD motor setting parameters ([Pr. PL_ _ ])
(Note)
0000 to 0005
4
Note. This is not available with the MR-J4-03A6(-RJ) servo amplifier.
(3) External I/O signals (command [9] [2])
Command
Data No.
Description
Setting range
Frame length
[9] [2]
[6] [0]
Communication input device signal
Refer to section
14.5.5.
8
(4) Alarm history (command [8] [2])
Command
Data No.
Description
Setting range
Frame length
[8] [2]
[2] [0]
Alarm history clear
1EA5
4
(5) Current alarm (command [8] [2])
Command
Data No.
Description
Setting range
Frame length
[8] [2]
[0] [0]
Alarm clear
1EA5
4
(6) I/O device prohibition (command [9] [0])
Command
Data No.
Description
Setting range
Frame length
[9] [0]
[0] [0]
Turns off the input device, external analog input signal or pulse train
input, except EMG, LSP and LSN, independently of the external on/off
status.
1EA5 4
[0] [3]
Disables all output devices (DO).
1EA5
4
[1] [0]
Cancels the prohibition of the input device, external analog input
signal or pulse train input, except EMG, LSP and LSN.
1EA5 4
[1] [3]
Cancels the prohibition of the output device.
1EA5
4
Содержание MR-J4-100A(-RJ)
Страница 19: ...10 MEMO ...
Страница 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Страница 83: ...2 INSTALLATION 2 8 MEMO ...
Страница 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 203: ...4 STARTUP 4 44 MEMO ...
Страница 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Страница 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 387: ...9 DIMENSIONS 9 22 MEMO ...
Страница 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Страница 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Страница 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Страница 856: ...APPENDIX App 41 ...
Страница 905: ...MEMO ...