![background image](http://html.mh-extra.com/html/mitsubishi-electric/mr-j4-100a-rj/mr-j4-100a-rj_instruction-manual_238540319.webp)
7. SPECIAL ADJUSTMENT FUNCTIONS
7 - 8
7.1.3 Shaft resonance suppression filter
POINT
This filter is set properly by default according to servo motor you use and load
moment of inertia. It is recommended that [Pr. PB23] be set to "_ _ _ 0"
(automatic setting) because changing "Shaft resonance suppression filter
selection" in [Pr. PB23] or [Pr. PB17 Shaft resonance suppression filter] may
lower the performance.
(1) Function
When a load is mounted to the servo motor shaft, resonance by shaft torsion during driving may
generate a mechanical vibration at high frequency. The shaft resonance suppression filter suppresses
the vibration.
When you select "Automatic setting", the filter will be set automatically on the basis of the motor you use
and the load to motor inertia ratio. The disabled setting increases the response of the servo amplifier for
high resonance frequency.
(2) Parameter
Set "Shaft resonance suppression filter selection" in [Pr. PB23].
[Pr. PB23]
Shaft resonance suppression filter selection
0: Automatic setting
1: Manual setting
2: Disabled
0 0 0
To set [Pr. PB17 Shaft resonance suppression filter] automatically, select "Automatic setting".
To set [Pr. PB17 Shaft resonance suppression filter] manually, select "Manual setting". The setting
values are as follows.
Shaft resonance suppression filter setting frequency selection
Setting
value
Frequency [Hz]
Setting
value
Frequency [Hz]
_ _ 0 0
Disabled
_ _ 1 0
562
_ _ 0 1
Disabled
_ _ 1 1
529
_ _ 0 2
4500
_ _ 1 2
500
_ _ 0 3
3000
_ _ 1 3
473
_ _ 0 4
2250
_ _ 1 4
450
_ _ 0 5
1800
_ _ 1 5
428
_ _ 0 6
1500
_ _ 1 6
409
_ _ 0 7
1285
_ _ 1 7
391
_ _ 0 8
1125
_ _ 1 8
375
_ _ 0 9
1000
_ _ 1 9
360
_ _ 0 A
900
_ _ 1 A
346
_ _ 0 B
818
_ _ 1 B
333
_ _ 0 C
750
_ _ 1 C
321
_ _ 0 D
692
_ _ 1 D
310
_ _ 0 E
642
_ _ 1 E
300
_ _ 0 F
600
_ _ 1 F
290
Содержание MR-J4-100A(-RJ)
Страница 19: ...10 MEMO ...
Страница 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Страница 83: ...2 INSTALLATION 2 8 MEMO ...
Страница 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 203: ...4 STARTUP 4 44 MEMO ...
Страница 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Страница 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 387: ...9 DIMENSIONS 9 22 MEMO ...
Страница 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Страница 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Страница 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Страница 856: ...APPENDIX App 41 ...
Страница 905: ...MEMO ...