TROUBLE SHOOTING

GUIDE

Содержание S Series

Страница 1: ...TROUBLE SHOOTING GUIDE...

Страница 2: ...TROUBEL SHOOTING GUIDE DYNAMIC TRIM CONTROL SYSTEM SERIES S Release R1A April 2019 Language English Copyright 2019 Zipwake AB Sweden All rights reserved www zipwake com...

Страница 3: ...r individual sets of error codes bit encoded The Distribution Unit DU S do not generate any error codes Presence of system error is indicated in the CP S display by a flashing red info symbol in combi...

Страница 4: ...er cooler location 64 GPS error No GPS signal Check GPS source and GPS status on the Select GPS source menu page norm set to Auto GPS signal is acquired received If an external GPS or NMEA 2000 GPS is...

Страница 5: ...d check that the blades are moving correctly run Interceptor Check 64 Electronics failure Electronics failure Restart the system power turned on main switch toggle Visit www zipwake com for upgrades r...

Страница 6: ...supply issue see previous check list 2 Check if the SU S that reports error operates makes any movement at system turn on 3 Replace SU S if confirmed it is not operating 6HUYR XQLW V VFUHZ VKDIW KDV E...

Страница 7: ...ase of any indication the blades are obstructed Interceptor Check readout not in the green range check for excessive marine growth dirt paint or sealant on interceptor s moving parts 2 Remove the Inte...

Страница 8: ...DFKHG GXULQJ 68 6 VWDUWXS VHTXHQFH 1 Remove any obstacles growth dirt mud paint etc that prevents the interceptor blade to fully retract 2 Check and verify the SU S is mounted with the screw shaft nut...

Страница 9: ...1 Check that the system units listed in the CP S under System Information agrees with the actually connected units 2 Check cable and connectors for dirt or damage Try connecting SU S to a different c...

Страница 10: ...onnect all units in the system except one CP S connected to the DU S on the I BUS OUT connection 2 Connect the SU S units one by one to the DU S at PORT3 connection and identify which SU S that trigge...

Страница 11: ...h designated torque 5 Nm Run the Interceptor Check and verify that the blades are moving freely within tolerance range all the readings of Interceptor Check are in green range Document and archive the...

Страница 12: ......