3. SIGNALS AND WIRING
3 - 24
(b) MR-J4-200A(-RJ)/MR-J4-350A(-RJ)
CNP2
CNP1
CNP3
MR-J4-200A(-RJ)
Servo amplifier
CNP3
CNP1
CNP2
MR-J4-350A(-RJ)
Servo amplifier
Table 3.2 Connector and applicable wire
Connector Receptacle
assembly
Applicable wire
Stripped
length [mm]
Open tool
Manufac
turer
Size Insulator
OD
CNP1 06JFAT-SAXGFK-XL
AWG 16 to 10
4.7 mm or shorter
11.5
J-FAT-OT-EXL JST
CNP3 03JFAT-SAXGFK-XL
CNP2
05JFAT-SAXGDK-H5.0
AWG 18 to 14
3.9 mm or shorter
9
(c) MR-J4-60A4(-RJ) to MR-J4-350A4(-RJ)
CNP2
CNP1
(Note)
CNP3
Servo amplifier
Note. A pin for preventing improper connection is inserted to N- of CNP1 connector.
Table 3.3 Connector and applicable wire
Connector Receptacle
assembly
Applicable wire
Stripped
length [mm]
Open tool
Manufac
turer
Size Insulator
OD
CNP1 06JFAT-SAXGDK-HT10.5
AWG 16 to 14
3.9 mm or shorter
10
J-FAT-OT-XL
JST
CNP2 05JFAT-SAXGDK-HT7.5
CNP3 03JFAT-SAXGDK-HT10.5
Содержание MR-J4-100A(-RJ)
Страница 19: ...10 MEMO ...
Страница 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Страница 83: ...2 INSTALLATION 2 8 MEMO ...
Страница 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 203: ...4 STARTUP 4 44 MEMO ...
Страница 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Страница 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 387: ...9 DIMENSIONS 9 22 MEMO ...
Страница 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Страница 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Страница 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Страница 856: ...APPENDIX App 41 ...
Страница 905: ...MEMO ...