![Mitsubishi Electric MR-J4-100A(-RJ) Скачать руководство пользователя страница 277](http://html.mh-extra.com/html/mitsubishi-electric/mr-j4-100a-rj/mr-j4-100a-rj_instruction-manual_238540277.webp)
5. PARAMETERS
5 - 74
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P S T
Po11
*OOP2
Function
selection O-2
Select the input devices of the analog speed command, analog speed limit and torque limit.
_ _ _ x For manufacturer setting
0h
_ _ x _ Override input CN1-2/CN20-2 switching selection
0: CN1-2 pin enabled
1: CN20-2 pin enabled
Setting "1" when no MR-D01 has been connected will trigger [AL. 37].
This parameter setting is available with MR-J4-_A_-RJ servo amplifiers with software
version B7 or later.
0h
_ x _ _ Torque limit CN1-27/CN20-12 switching selection
0: CN1-27 pin enabled
1: CN20-12 pin enabled
Setting "1" when no MR-D01 has been connected will trigger [AL. 37].
This parameter setting is available with MR-J4-_A_-RJ servo amplifiers with software
version B7 or later.
0h
x _ _ _ For manufacturer setting
0h
Po12
*OOP3
Function
selection O-3
Select an alarm code output setting and an M code output setting.
_ _ _ x MR-D01 alarm code output
0: Disabled
1: Enabled
Selecting "1" in this digit will output an alarm code when an alarm occurs.
This parameter setting is available with servo amplifiers with software version B7 or
later.
This parameter setting is available with MR-J4-_A_-RJ servo amplifiers with software
version B7 or later.
0h
_ _ x _ For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
Содержание MR-J4-100A(-RJ)
Страница 19: ...10 MEMO ...
Страница 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Страница 83: ...2 INSTALLATION 2 8 MEMO ...
Страница 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 203: ...4 STARTUP 4 44 MEMO ...
Страница 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Страница 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 387: ...9 DIMENSIONS 9 22 MEMO ...
Страница 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Страница 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Страница 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Страница 856: ...APPENDIX App 41 ...
Страница 905: ...MEMO ...