18. MR-J4-03A6(-RJ) SERVO AMPLIFIER
18 - 65
(b) Parameters of 4 to 6 decimal digits
The following example gives the operation procedure to change [Pr. PB03 Positioning command
acceleration/deceleration time constants (position smoothing)] to "65535".
Press "MODE" to switch to the gain/filter setting parameter screen.
Press "UP" or "DOWN" to select [Pr. PB03].
The display blinks
(Note 1)
Press the "SET" button once.
Press the "SET" button once.
Upper 3 digit
Change the setting with the
"UP" or "DOWN" button.
Press the "SET" button once.
Enter the setting.
(Note 2)
Press the "MODE" button once.
Press the "MODE" button once.
Lower 3 digits
……
……
……
…
Note 1. Pressing the "SET" button in either upper or lower 3-digit display makes the
display blink.
2. Pressing the "SET" button in either upper or lower 3-digit display fix the setting.
The display can be switched between upper and lower 3-digit by pressing the "MODE" button.
Switching the display between upper and lower 3-digit is also possible by pressing the "MODE"
button while the display is blinking.
The changed value will be canceled when "MODE" is pressed for 2 s or more while blinking.
To shift to the next parameter number, press the "UP" or "DOWN" button.
To change the screen to the other, press "UP" or "DOWN" to change the screen to other parameter
number display screen and press "MODE".
Содержание MR-J4-100A(-RJ)
Страница 19: ...10 MEMO ...
Страница 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Страница 83: ...2 INSTALLATION 2 8 MEMO ...
Страница 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 203: ...4 STARTUP 4 44 MEMO ...
Страница 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Страница 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 387: ...9 DIMENSIONS 9 22 MEMO ...
Страница 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Страница 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Страница 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Страница 856: ...APPENDIX App 41 ...
Страница 905: ...MEMO ...