(1) For main circuit power supply
When using a fuse instead of the molded-case circuit breaker, use the one having the specifications
given in this section.
Servo amplifier
Molded-case circuit breaker (Note 1, 4)
Fuse
Magnetic
contactor
(Note 2)
Frame, rated current
Voltage AC
[V]
Class Current
[A]
Voltage AC
[V]
Power factor
improving reactor is
not used
Power factor
improving reactor is
used
MR-J4-10A(-RJ)
30 A frame 5 A
30 A frame 5 A
240 T
10
300
S-N10
S-T10
MR-J4-20A(-RJ)
30 A frame 5 A
30 A frame 5 A
MR-J4-40A(-RJ)
30 A frame 10 A
30 A frame 5 A
15
MR-J4-60A(-RJ)
30 A frame 15 A
30 A frame 10 A
20
MR-J4-70A(-RJ)
30 A frame 15 A
30 A frame 10 A
MR-J4-100A(-RJ)
(3-phase power
supply input)
30 A frame 15 A
30 A frame 10 A
MR-J4-100A(-RJ)
(1-phase power
supply input)
30 A frame 15 A
30 A frame 15 A
30
MR-J4-200A(-RJ) 30 A frame 20 A
30 A frame 20 A
40
S-N20
(Note 3)
S-T21
MR-J4-350A(-RJ) 30 A frame 30 A
30 A frame 30 A
70
S-N20
S-T21
MR-J4-500A(-RJ) 50 A frame 50 A
50 A frame 50 A
125
S-N35
S-T35
MR-J4-700A(-RJ) 100 A frame 75 A
60 A frame 60 A
150
S-N50
S-T50
MR-J4-11KA(-RJ) 100 A frame 100 A
100 A frame 100 A
200
MR-J4-15KA(-RJ) 125 A frame 125 A
125 A frame 125 A
250
S-N65
S-T65
MR-J4-22KA(-RJ) 225 A frame 175 A
225 A frame 175 A
350
S-N95
S-T100
MR-J4-60A4(-RJ) 30 A frame 5 A
30 A frame 5 A
480 T
10
600
S-N10
S-T10
MR-J4-100A4(-RJ) 30 A frame 10 A
30 A frame 5 A
15
MR-J4-200A4(-RJ) 30 A frame 15 A
30 A frame 10 A
25
MR-J4-350A4(-RJ) 30 A frame 20 A
30 A frame 15 A
35
S-N20
(Note 3)
S-T21
MR-J4-500A4(-RJ) 30 A frame 20 A
30 A frame 20 A
50
MR-J4-700A4(-RJ) 30 A frame 30 A
30 A frame 30 A
65
S-N20
S-T21
MR-J4-11KA4(-RJ) 50 A frame 50 A
50 A frame 50 A
100
S-N25
S-T35
MR-J4-15KA4(-RJ) 60 A frame 60 A
60 A frame 60 A
150
S-N35
S-T35
MR-J4-22KA4(-RJ) 100 A frame 100 A
100 A frame 100 A
175
S-N50
S-T50
MR-J4-10A1(-RJ) 30 A frame 5 A
30 A frame 5 A
240 T
10
300
S-N10
S-T10
MR-J4-20A1(-RJ) 30 A frame 10 A
30 A frame 10 A
15
MR-J4-40A1(-RJ) 30 A frame 15 A
30 A frame 10 A
20
Note 1. When having the servo amplifier comply with the IEC/EN/UL/CSA standard, refer to app. 4.
2. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less.
3. S-N18 can be used when auxiliary contact is not required.
4. Use a molded-case circuit breaker having the operation characteristics equal to or higher than Mitsubishi Electric general-
purpose products.
Содержание MR-J4-100A(-RJ)
Страница 19: ...10 MEMO ...
Страница 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Страница 83: ...2 INSTALLATION 2 8 MEMO ...
Страница 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 203: ...4 STARTUP 4 44 MEMO ...
Страница 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Страница 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 387: ...9 DIMENSIONS 9 22 MEMO ...
Страница 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Страница 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Страница 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Страница 856: ...APPENDIX App 41 ...
Страница 905: ...MEMO ...