11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 102
11.16 EMC filter (recommended)
POINT
For when multiple servo amplifiers are connected to one EMC filter, refer to
section 6.4 of "EMC Installation Guidelines".
It is recommended that one of the following filters be used to comply with EN EMC directive. Some EMC
filters have large in leakage current.
(1) Combination with the servo amplifier
Servo amplifier
Recommended filter (Soshin Electric)
Mass [kg]
Model
Rated current [A]
Rated voltage
[VAC]
Leakage current
[mA]
MR-J4-10A(-RJ) to
MR-J4-100A(-RJ)
HF3010A-UN
(Note)
10
250
5
3.5
MR-J4-200A(-RJ)
MR-J4-350A(-RJ)
HF3010A-UN
(Note)
30 5.5
MR-J4-500A(-RJ)
MR-J4-700A(-RJ)
HF3040A-UN
(Note)
40
6.5
6
MR-J4-11KA(-RJ)
MR-J4-15KA(-RJ)
MR-J4-22KA(-RJ)
HF3100A-UN
(Note)
100 12
MR-J4-60A4(-RJ)
MR-J4-100A4(-RJ)
TF3005C-TX 5
6
MR-J4-200A4(-RJ) to
MR-J4-700A4(-RJ)
TF3020C-TX 20
500 5.5
MR-J4-11KA4(-RJ) TF3030C-TX
30
7.5
MR-J4-15KA4(-RJ) TF3040C-TX
40
12.5
MR-J4-22KA4(-RJ) TF3060C-TX
60
MR-J4-10A1(-RJ) to
MR-J4-40A1(-RJ)
HF3010A-UN
(Note)
10 250 5 3.5
Note. To use any of these EMC filters, the surge protector RSPD-500-U4 (Okaya Electric Industries) is required.
Servo amplifier
Recommended filter (COSEL)
Mass [kg]
Model
Rated current [A]
Rated voltage
[VAC]
Leakage current
[mA]
MR-J4-11KA(-RJ) to
MR-J4-22KA(-RJ)
FTB-100-355-L
(Note)
100 500 40 5.3
MR-J4-22KA4(-RJ)
FTB-80-355-L
(Note)
80 500 80
5.3
Note. To use any of these EMC filters, the surge protector RSPD-500-U4 (Okaya Electric Industries) is required.
Содержание MR-J4-100A(-RJ)
Страница 19: ...10 MEMO ...
Страница 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Страница 83: ...2 INSTALLATION 2 8 MEMO ...
Страница 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 203: ...4 STARTUP 4 44 MEMO ...
Страница 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Страница 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 387: ...9 DIMENSIONS 9 22 MEMO ...
Страница 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Страница 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Страница 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Страница 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Страница 856: ...APPENDIX App 41 ...
Страница 905: ...MEMO ...