Windsor 500 Programming Manual - Issue C
- 22 -
Windsor Device 17 pin assignments for a Dialler
CON4/7
Pin No
Description
(Typical Functions)
Channel
Type
Windsor
TX Number
1
Fire
1
Input
1
2
PA
2
Input
2
3
Intruder
3
Input
3
4
Open/Close
4
Input
4
5
Trouble
5
Input
5
6
Tell Back
Output
7
Comms Fail
Output
8
Low Battery
9
Input
6
9
12v
Power
10
0v
Power
11
Spare
12
5v
Power
13
Technical Alarm
6
Input
14
Alarm confirmation
7
Input
8
15
Line fault
Output
16
2 way speech
8
Input
7
To view or modify the plug on comm option select 3 from the hardware menu.
Plug On Comm
Off
Help menu
Press HELP for a list of the plug on comm types.
1=Std.STU
2=STU Type 3G
Plug on comm type menu
STU
If a STU is programmed LK7 on the main PCB
11
should be fitted in the STU position. LK7
controls the signal on pin 16 of the plug on communicator. See the device pin assignments
table for further details.
The standard STU inverts the polarity of the signal on pin 4. When device 17 is programmed
as a STU Windsor will compensate for this inversion. For this reason if the signals on
CON4/7 are measured pin 4 will be inverted (when compared to the other channels).
Windsor will ignore the TX invert option when the communicator is a standard STU or 3G
STU.
Hardware menu
Sndr.Invert
The sounder relay on the Windsor main PCB is normally de-energised. This can be changed
to be normally energised by turning on the sounder invert option. The sounder relay has NO
and NC connections.
11
Windsor Mark 1 main PCB only (PC787).