Windsor 500 Programming Manual - Issue C
- 49 -
Keypad LED Functions
LED
Product
Function
Mains
Keypad,
Keypoint,
Cardpoint
If the mains is present the mains LED will be on continuously. If
the mains is not present for more than 5 minutes the mains LED
will be flashed. If the supply voltage falls to the low volts
threshold the mains LED will be turned off.
Day
Keypad,
Keypoint,
Cardpoint
When a user logs on to a keypad the day LED will be turned on if
all authorised areas are unset. During setting the day LED will
flash.
Ready
Keypad,
Keypoint,
Cardpoint
When a user logs on to a keypad the ready LED will be turned
on if all authorised areas are clear. An area is clear if the alarm
log is empty, all area circuits with a set response are clear, all
NA area circuits are clear and an engineer reset is not required.
Message
Keypad,
Keypoint,
Cardpoint
The message LED will be turned on if an entry is made to a
keypad alarm log or the system log. The message LED is
cleared when the log is clear.
Call engineer
Keypad
The call engineer LED is turned on when an engineer reset is
required. It will be turned off when an engineer PIN code is
entered, the panel is reset from GCM or if a customer engineer
reset PIN code is used.
Line fault
Keypad
This LED is on, when the system is unset, if a line fault is
present or if Windsor does not receive a comm acknowledge
from a central station to all call attempts.
Late working
Keypad
The late working LED is on when late working is selected for the
current day.
Set warning
Keypad
The set warning LED is on during the set warning period even if
no user is logged on.