1
❶
Mount the detector.
❷
Wire the detector.
❹
Test the detector.
❸
Configure the detector.
FG-1525R/FG-1525RT Glassbreak Detector Installation Instructions
For location guidelines, refer to the Supplemental
Information on the back page.
Note:
If you plan to use the wall tamper, locate the
wall tamper screw position before the mounting
screws position. Refer to the Supplemental Informa-
tion for instructions on using the wall tamper.
•
Use a screwdriver to push down on the latch at the
side of the detector to remove the front cover.
Note:
Do not remove the PCB from the protective
enclosure.
•
For surface wiring, use the FG-SP2 spacer plate
provided.
•
Secure the detector with #6 (M3.5) or #8 (M4)
screws (not provided).
•
Route the wire through the wire entry hole in the
PCB center. Cut and strip wire ends 1/4 inch
(6.5 mm).
•
Wire the detector using 18-22 AWG (0.64 mm to
1.02 mm). Reverse polarity connections will not
damage the detector. For proper wiring methods,
refer to the National Electrical Code NFPA 70.
•
After completing wiring, push excess wire back
into the wall and replace the front cover.
Note:
You can secure the cover with a #4 (M3) screw
if required. The hole is located on the intermediate
cover near the latch.
Note:
Test the FG-1525R/RT at least once each year.
Test the detector with the FG-701 Glassbreak
Simulator. The FG-700 can be used if set for
TEMPered glass sound.
Activating Test Mode
1
Position the simulator within 15 (4.6 m) of the
FG-1525R/RT detector.
2
Switch the FG-701 simulator to ACTIVATE and
MANual modes.
3
Point the front of the simulator at the detector and
press the red start button.
The simulator buzzes, and the green LED on the
FG-1525R/RT flashes about once per second to
indicate it is in Test Mode.
If an FG-701 is not available, or if for any reason
remote activation cannot be used, use a small
screwdriver to short the test pads on the PCB. This
activates Test Mode.
TIP:
Temporarily mount the detector in the intended
location and power it with a 9 V battery until testing
establishes effective range coverage. If the 9 V
battery is low, both LEDs will flash.
Make sure to replace the front cover of the unit before
testing.
Testing the FG-1525R/RT
1
Set the FG-701 switches to the TEST and FLEX
positions.
2
Position the FG-701 near the farthest point of the
glass and point it directly at the FG-1525R/RT. If
window coverings are present, close them fully
and hold the FG-701 behind them.
3
Press the red start button. The simulator clicks
on and starts an 8 second armed period.
4
Generate a flex signal by carefully striking the
glass with a cushioned tool. The FG-701 responds
by producing a burst of glassbreak audio.
If the FG-1525R/RT properly receives both the
simulator flex and audio, the red alarm LED lights.
Note:
Some environmental factors may reduce the detector activation
range. If after pressing the red start button you do not see the green
LED flashing, move closer to the detector and try again.
Testing the Audio Alone
You can also use the simulator in the MANual mode to test audio alone.
The green LED on the detector flickers when the detector properly
receives the simulator audio. (See the FG-701 Operating Instructions
for additional information.) Keep in mind this is not a complete test.
Exiting Test Mode
After testing, exit Test Mode using the same procedure for activating
Test Mode. The FG-1525R/RT also automatically exits Test Mode after
10 minutes.
NC loop, no EOL resistor
NO loop, no EOL resistor
(FG-1525RT only)
NC loop with EOL resistor
NO loop with EOL resistor
(FG-152RT only)
The following tables show how to
configure DIP switch S2 to best suit
the application.
SWITCH
ON
OFF
LATCH
SENS1
OFF
ON
OFF
ON
Red Alarm LED latches
ON when detector goes
into alarm.
2,3
LEDs are disabled except
during power-up and Test
Mode.
4
LEDs are always enabled.
No effect in Remote LED
Enable/Disable Mode.
1
Verify range with the FG-701.
2
The timing of the alarm relay is not affected by the latched Alarm LED.
3
Reset the Alarm LED by removing and restoring power, or by toggling
the detector in and out of test mode.
4
LEDs can be enabled or disabled with the FG-701.
LED
SENS2
OFF
OFF
ON
ON
SENSITIVITY
1
Max
Med
Low
Lowest
APPROX. RANGE
25 (7.6 m)
15 (4.6 m)
10 (3 m)
5(1.5 m)
= Default Settings
Red Alarm LED lights for 5
seconds during alarm.
Tamper
Terminal Blocks
Wire
Entry
Hole
LEDs
Microphone
DIP Switch
Alarm
Form A
Power
25 mA at
12 VDC
Tamper Switch
REMOTE LED ENABLE/DISABLE MODE
The detectors Remote LED Enable/Disable Mode allows you to enable or
disable the detectors LEDs with the FG-701 Glassbreak Simulator.
To enable or disable the LEDs with the FG-701:
1. Set LED switch, S4 position 4, to off.
2. Set the FG-701 switches to the ACTIVATE and MANual positions.
3. Stand within 4.6 m (15 feet) of the detector, point the front of the
FG-701 at the detector, and press the red START button. The simu-
lator generates an audio activation signal, and the detectors green
LED flashes once per second.
4. Repeat step 3, and the detectors green LED will stop flashing.
5. Within 2 seconds, repeat step 3 to send another activation code. If
disabling the LEDs, the detectors green LED will flash once. If en-
abling the LEDs, the green LED will flash two to three times.
6. Clap your hands to test the LEDs. If the LEDs are enabled, the green
LED will flicker. If the LEDs are disabled, the green LED will remain
off.