background image

1

  

Mount the detector.

  

Wire the detector.

 

 Test the detector.

  

Configure the detector.

FG-1525R/FG-1525RT Glassbreak Detector Installation Instructions

For location guidelines, refer to the Supplemental

Information on the back page.

Note:

 If you plan to use the wall tamper, locate the

wall tamper screw position before the mounting

screws position. Refer to the Supplemental Informa-

tion for instructions on using the wall tamper.

Use a screwdriver to push down on the latch at the

side of the detector to remove the front cover.

Note:

 Do not remove the PCB from the protective

enclosure.

For surface wiring, use the FG-SP2 spacer plate

provided.

Secure the detector with #6 (M3.5) or #8 (M4)

screws (not provided).

Route the wire through the wire entry hole in the

PCB center. Cut and strip wire ends 1/4 inch

(6.5 mm).

Wire the detector using 18-22 AWG (0.64 mm to

1.02 mm). Reverse polarity connections will not

damage the detector. For proper wiring methods,

refer to the National Electrical Code NFPA 70.

After completing wiring, push excess wire back

into the wall and replace the front cover.

Note:

 You can secure the cover with a #4 (M3) screw

if required.  The hole is located on the intermediate

cover near the latch.

Note:

 Test the FG-1525R/RT at least once each year.

Test the detector with the FG-701 Glassbreak

Simulator. The FG-700 can be used if set for

TEMPered glass sound.

Activating Test Mode
1

Position the simulator within 15’ (4.6 m) of the

FG-1525R/RT  detector.

2

Switch the FG-701 simulator to ACTIVATE and

MANual modes.

3

Point the front of the simulator at the detector and

press the red start button.

The simulator buzzes, and the green LED on the

FG-1525R/RT flashes about once per second to

indicate it is in Test Mode.
If an FG-701 is not available, or if for any reason

remote activation cannot be used, use a small

screwdriver to short the test pads on the PCB. This

activates Test Mode.

TIP:  

Temporarily mount the detector in the intended

location and power it with a 9 V battery until testing

establishes effective range coverage.  If the 9 V

battery is low, both LEDs will flash.

Make sure to replace the front cover of the unit before

testing.

Testing the FG-1525R/RT
1

Set the FG-701 switches to the TEST and FLEX

positions.

2

Position the FG-701 near the farthest point of the

glass and point it directly at the FG-1525R/RT. If

window coverings are present, close them fully

and hold the FG-701 behind them.

3

Press the red start button. The simulator “clicks”

on and starts an 8 second armed period.

4

Generate a flex signal by carefully striking the

glass with a cushioned tool. The FG-701 responds

by producing a burst of glassbreak audio.

If the FG-1525R/RT properly receives both the

simulator flex and audio, the red alarm LED lights.

Note: 

  Some  environmental  factors  may  reduce  the  detector  activation

range. If after pressing the red start button you do not see the green

LED flashing, move closer to the detector and try again.

Testing the Audio Alone

You can also use the simulator in the MANual mode to test audio alone.

The green LED on the detector flickers when the detector properly

receives the simulator audio. (See the FG-701 Operating Instructions

for additional information.) Keep in mind this is not a complete test.

Exiting  Test  Mode

After testing, exit Test Mode using the same procedure for activating

Test Mode. The FG-1525R/RT also automatically exits Test Mode after

10 minutes.

NC loop, no EOL resistor

NO loop, no EOL resistor

(FG-1525RT only)

NC loop with EOL resistor

NO loop with EOL resistor

(FG-152RT  only)

The following tables show how to

configure DIP switch S2 to best suit

the application.

SWITCH

   ON

OFF

LATCH

SENS1

OFF

ON

OFF

ON

Red Alarm LED latches

ON when detector goes

into alarm.

2,3

LEDs are disabled except

during power-up and Test

Mode. 

4

LEDs are always enabled.

No effect in Remote LED

Enable/Disable Mode.

1

Verify range with the FG-701.

2

The timing of the alarm relay is not affected by the latched Alarm LED.

3

Reset the Alarm LED by removing and restoring power, or by toggling

the detector in and out of test mode.

4

LEDs can be enabled or disabled with the FG-701.

LED

SENS2

OFF

OFF

ON

ON

SENSITIVITY

1

Max

Med

Low

Lowest

APPROX. RANGE

25’ (7.6 m)

15’ (4.6 m)

10’ (3 m)

5’(1.5 m)

= Default Settings

Red Alarm LED lights for 5

seconds during alarm.

     Tamper

Terminal Blocks

Wire

Entry

Hole

LEDs

Microphone

DIP Switch

Alarm

Form A

Power

25 mA at

12  VDC

Tamper  Switch

REMOTE  LED  ENABLE/DISABLE  MODE

The detector’s Remote LED Enable/Disable Mode allows you to enable or

disable the detector’s LEDs with the FG-701 Glassbreak Simulator.

To enable or disable the LEDs with the FG-701:

1. Set LED switch, S4 position 4, to off.

2. Set the FG-701 switches to the ACTIVATE and MANual positions.

3. Stand within 4.6 m (15 feet) of the detector, point the front of the

FG-701 at the detector, and press the red START button.  The simu-

lator generates an audio activation signal, and the detector’s green

LED flashes once per second.

4. Repeat step 3, and the detector’s green LED will stop flashing.

5. Within 2 seconds, repeat step 3 to send another activation code. If

disabling the LEDs, the detector’s green LED will flash once. If en-

abling the LEDs, the green LED will flash two to three times.

6. Clap your hands to test the LEDs. If the LEDs are enabled, the green

LED will flicker. If the LEDs are disabled, the green LED will remain

off.

Отзывы: