Windsor 500 Programming Manual - Issue C
- 74 -
Comms menu
Tel. Line
To view or modify the telephone line options select option 3 from the comms menu.
Dial Type-DTMF
Set Flt-Off
Lnft Warn-On
Lnft Enable-30
Line Block-Off
Handset-Off
Blind Dial-Off
Recall-On
Tel. Line menu
Dial Type
The choices are pulse or DTMF. If you are unsure if your local exchange supports DTMF
dialling then program pulse.
Tel. Line menu
Set Flt
Windsor will only allow an area to be set with a line fault present if the Set Flt option is on.
Tel. Line menu
Lnft Warn
The normal line fault response includes an audible warning when unset. The audible response
can be disabled using the Lnft Warn option.
Lnft Warn
On
On/Off
Tel. Line menu
Lnft Enable
Normally a line fault must be present for 30 seconds before a line fault is recognised by the
control panel. This delay period can up to 255 seconds. If a value of 0 is programmed then
line faults will not be recognised. Line fault disabling is only recommended in installations
where the communicator is sharing a telephone line with other equipment which may be in use
for more than the maximum line fault delay (see also the handset option).
Lnft Enable
30
0-255 seconds
A Windsor modem can differentiate between a line fault and other equipment in use and, in
this case, there is no need to disable line fault monitoring under any circumstances.
Tel. Line menu
Line Block
This option is only required if you are using SmartDial. Consult your SmartDial manual for
more details.