Sovereign and the early Windsor mark 1 concentrators are NEOL-1 types. NEOL-2
concentrators can detect and report when a fuse is blown. There is no difference in the circuit
wiring of a NEOL-1 and NEOL-2.
Concentrator menu
Outputs
Each concentrator has two programmable outputs which are controlled from Windsor. An
optional 8 channel output module (daughter board) may be fitted to each external concentrator.
Outputs 1 and 2 have 6 programmable options which may be selected for any area.
Concentrator Output 1 & 2 Functions
Function name
Description
Latch Freeze
This output is active low when a circuit in the programmed area alarms. It
remains active until the area is next set or reset.
Set/Unset
This output is active high when the selected area(s) is set. It remains
active until the area(s) is unset.
Walk Test
This output is active high during walk testing. It remains active until the
walk test is completed.
Detector Test
This output is active high during the detector test period.
Power Reset
This output is active low for 5 seconds during a reset if a fire alarm or night
alarm circuit has been activated.
Setting
This output is active high during the area setting exit time.
Each external concentrator may have an 8 output daughter board fitted. The daughter board
outputs may be programmed for 4 different functions.
External Concentrator Output 3 (Daughter board) Functions
Function name
Description
TX Data
Transmitter channel data for the programmed device.
Alarm Status
The real time alarm status of the programmed concentrator circuit inputs.
Alarm
The latched alarm status of the programmed concentrator circuit inputs.
Mimic
As alarm but the indication is not cleared when the circuits are auto-reset.
To view or modify a concentrator output configuration select option 1 from the concentrator
menu and then enter the output number.
Conc-01 O/P 1
L.Freeze Area-1
Help menu
1=L.Freeze
There are 6 options for outputs 1 and 2.
2=Set/Uns
3=Power Rst
4=Det Test
5=Walk Test
6=Setting
The programming options for output 3 are different. A device number must also be
programmed for output 3.
1=Cct Status
There are 4 options for output 3.
2=Cct Alarm
3=TX Data
4=Mimic Data
If output 3 is programmed for TX data the daughter board outputs will follow the status of the
programmed device number (1-19) channels. The same device number can be programmed
Содержание Windsor 500
Страница 1: ...Windsor 500 Programming Manual Issue C ...
Страница 39: ...Windsor 500 Programming Manual Issue C 39 Log On On Off ...
Страница 54: ...Windsor 500 Programming Manual Issue C 54 TX Reset Normal Help Menu ...
Страница 108: ...Guardall Limited Lochend Industrial Estate Newbridge Edinburgh EH28 8PL Scotland Part No 320488 Issue C ...