Windsor 500 Programming Manual - Issue C
- 91 -
EvProg Schedule Menu
Open 1
The event programmer unsetting restrictions apply during the open close period on days
which are not omitted and not programmed as a holiday. The unsetting restrictions will be
affected by the area control options; vault timer and alarm unset. As an example consider an
area schedule with an open 1 time of 08:00, a close 1 time of 10:00 and open 2 time of 13:00,
a close 2 time of 15:00. Unsetting is allowed only between 08:00 and 10:00 and between
13:00 and 15:00.
24:00
08:00
10:00
13:0
0
15:00
In an HS event programmer the Open 1 time is the earliest time that all areas programmed to
use the schedule can be unset. An area can be set and unset without restriction between the
open and close times. If a day has no open 1 time programmed then the area is
considered to be omitted from the schedule and cannot be unset until the next day the
schedule operates.
Mon Open 1
00:00
Time of day
EvProg Schedule Menu
Close 1
In an HS event programmer this is the latest time that all areas programmed to use the
schedule can be unset. If an area is not unset by this time then it cannot be unset until the next
day the schedule applies (day not omitted and not a holiday).
Mon Close 1
00:00
Time of day
If an event programmer area is set after the close time then it cannot be unset until the next
open time unless the unset after an alarm condition applies. An area can be set and unset
freely within the open/close period (s).
EvProg Schedule Menu
Set 1
Windsor will automatically set all areas programmed to use the schedule at the programmed
set 1 time if the programmed time is not 00:00.
If later working is required on a particular day(s) then a later than normal time can be
programmed for Set 1. If a user temporary Late Work option is required then it is necessary to
program a Set 1 and Set 2 time. If permanent late working is required program a Set 2 time
and no Set 1 time.
Mon Set 1
00:00
Time of day
If a user logs on during the set 2 warning period a later set time may be entered. The new set
1 time should be before schedule start time.