Light zone menu
Manual
A zone can be turned on/off manually by the user. The engineer can program an on duration
in the range 1-255 minutes. Windsor will automatically turn off the zone output at the end of
this period.
Light zone menu
Test
Excalibur trigger circuits are not associated with a Windsor area and are therefore not tested
as part of the normal area walk test. To test the Excalibur trigger circuits select test from the
light zone menu. Testing is disabled if the light zone daylight input is in the night condition.