Windsor 500 Programming Manual - Issue C
- 78 -
System TX Function
P.Fail
This output will be turned on when the supply voltage falls to the power fail threshold. It will be
turned off when the supply voltage exceeds the power fail threshold.
System TX Function
Pow.On
This output will be turned on when power is applied. It will be turned off after 10 seconds.
System TX Function
UI Fire
This output will be turned on if user activates the UI fire buttons. It will be turned off when a
user resets.
System TX Function
UI Med.
This output will be turned on if user activates the UI medical buttons. It will be turned off when
a user resets.
System TX Function
UI PA
This output will be turned on if user activates the UI PA buttons. It will be turned off when a
user resets.
System TX Function
Set
This output will be turned on when all areas are set. It will be turned off when any area unsets.
System TX Function
Battery Test
This output will be turned on if the battery voltage is low during an automatic battery test. It will
be turned off if the battery condition is OK when a user resets.
System TX Function
Rem.Alm
This output will be turned on if a remote communication alarm occurs. It will be turned off when
a user resets.
System TX Function
Daily
This output will be turned on if no other channel on the device programmed for the daily
function has activated in the previous 24 hour period. It will be turned off automatically after 10
seconds.
System TX Function
Alarm Abort
This output will be turned on for 3 seconds if a user aborts an alarm transmission.
Содержание Windsor 500
Страница 1: ...Windsor 500 Programming Manual Issue C ...
Страница 39: ...Windsor 500 Programming Manual Issue C 39 Log On On Off ...
Страница 54: ...Windsor 500 Programming Manual Issue C 54 TX Reset Normal Help Menu ...
Страница 108: ...Guardall Limited Lochend Industrial Estate Newbridge Edinburgh EH28 8PL Scotland Part No 320488 Issue C ...