Windsor 500 Programming Manual - Issue C
- 47 -
KP menu
EKP Set Mode
If the KP type is a keypoint or INOVA Cardpoint then option 2 will be available. This will allow a
single area to be programmed.
KP-1
Instant Area-1
Help menu
See KP set mode for a list of the setting options.
KP menu
KP Set Mode
The keypad set mode on an LCD keypad can be different for each area. To view or modify the
KP set mode select option 1 from the keypad menu and then enter the area number.
KP-1 Area-1
Instant
Help menu
For a list of setting modes press HELP.
0=Off
There are 7 setting mode menu options.
1=Timed
2=Instant
3=PB
4=EnEx
5=EnEx/Tm
6=Unset
Unset mode cannot be programmed for the system.
KP set mode menu
Off
If an area is programmed as off no user can access this area from the keypad being
programmed. This rule applies to all operations, not just setting, and to all users including the
engineer. This programming selection can only be reversed by re-programming the keypad on
a keypad with authority over the area programmed for off (Keypad 0 will always allow access
to all areas).
KP set mode menu
Timed
If timed setting is programmed an exit time in the range 1-255 seconds must be also
programmed. Windsor will attempt to set the programmed area at the end of the exit time.
KP set mode menu
Instant
If Instant setting is programmed for the area Windsor will attempt to set when the user
requests setting. There will still be a short delay before an area “Instant” sets to allow all
circuits to be checked. The length of the delay will depend on the number of concentrators
and whether set battery testing is enabled.
KP set mode menu
PB
If push button (PB) setting is programmed for the area Windsor will attempt to set when the
user activates the PB circuit after the final exit circuit, which is programmed to operate with
the PB circuit, has been closed.