Windsor 500 Programming Manual - Issue C
- 21 -
Serial port type menu
Windsor Modem
The Windsor modem may be connected directly to the Windsor serial port. Refer to the
installation manual for mounting details. The baud rate is fixed at 2400
9
. The Windsor modem
can be used for all engineering communications and alarm reporting in Ademco fast format,
point ID and Guardall formats.
Serial Port
Baud-2400
Help menu
Serial port type menu
Mimic
Windsor can report alarm events to the Micromimic graphical mimic interface. All circuit and
system alarm events will be reported in real time. The baud rate for mimic is fixed at 1200.
Selecting mimic will disable real time printing.
Hardware menu
Plug On Comm
The plug on communicator (CON4/7) is used to connect to a STU. Windsor identifies the plug
on communicator as device number 17
10
.
Windsor Device 17 pin assignments
CON4/7 pin
Windsor Reference
STU Function
Dialler Function
1
TX 1
Alarm 1
Channel 1
2
TX 2
Alarm 2
Channel 2
3
TX 3
Alarm 3
Channel 3
4
TX 4
Alarm 4
Channel 4
5
TX 5
Alarm 5 or 7 (link 2 on STU) Channel 5
6
Return Path Signal
Return Path Signal
Tell Back
7
Not Used
Not Used
Comm Fail
8
TX 6
Low Battery
Low Battery
9
12 Volts
12 Volts
12 Volts
10
0 Volts
0 Volts
0 Volts
11
Not Used
Not Used
Not Used
12
5 Volts
5 Volts
5 Volts
13
Not Used
Not Used
Channel 6
14
TX 8
Alarm 6
Channel 7
15
Line fault
Line fault
Line fault (0v=OK)
16
TX 7
Alarm 8
Not Used
9
If the Windsor modem is connected to a SmartComm RX it will change automatically to 1200 half
duplex.
10
This was device 9 in versions prior to 3.00.