Windsor 500 Programming Manual - Issue C
- 13 -
Edit page 1
Defaults
The defaults menu will only be displayed if the engineer PIN code is the first PIN code to be
entered after power up. To default the configuration select option 0 from page 1 of the edit
menus.
1=Config
2=Text
There are 5 default menu options.
3=User PINs
4=Eng PIN
5=PIN of Day Key
When a default option is selected Windsor will display the following message;
Loading Defaults
On a Windsor mark 1 pressing any key during this time will clear
Please Wait ...
the message but the configuration will be defaulted. On
Windsor 500, fitted with an EEPROM, key presses will be
ignored until the configuration is defaulted.
Defaulting an EEPROM on a Windsor 500 will take approximately 30 seconds.
Windsor can also be defaulted by powering up with I/P2 (CON2
1
) connected to 0 volts or by
connecting CON13-2
2
to 12 volts. When the time/date appears on a keypad the configuration
will have been defaulted. The 0 or 12 volt connection must then be removed otherwise all
subsequent changes to the configuration will not be saved. In v3.00 only the configuration will
be defaulted, in earlier versions the configuration and the logs will be defaulted. When the
configuration is defaulted a “Restored PIN(s)” entry is made in the event log.
Defaults menu
Config
The configuration option will default all configuration except the text descriptors and the PIN
codes.
Defaults menu
Text
The text option will default the text descriptors for circuits, users, areas, bypass groups and
the company name.
Defaults menu
User PINs
The user PINs option will default all user identification codes, except the engineer PIN code, to
the default PIN codes. All users identified by a SmartKey or INOVA card will also be set to the
default PIN code, thereby rendering the programmed electronic keys and INOVA cards invalid.
When the PIN codes are defaulted a “Restored PIN(s)” entry is made in the event log.
Defaults menu
Eng PIN
The engineer PIN code option is only available when the PIN of the day option is off. When the
engineer PIN code is defaulted a “Restored PIN(s)” entry is made in the event log.
1
Windsor Mark 1 main PCB (PC787).
2
Windsor 500 main PCB (PC820).
Содержание Windsor 500
Страница 1: ...Windsor 500 Programming Manual Issue C ...
Страница 39: ...Windsor 500 Programming Manual Issue C 39 Log On On Off ...
Страница 54: ...Windsor 500 Programming Manual Issue C 54 TX Reset Normal Help Menu ...
Страница 108: ...Guardall Limited Lochend Industrial Estate Newbridge Edinburgh EH28 8PL Scotland Part No 320488 Issue C ...