Windsor 500 Programming Manual - Issue C
- 14 -
Defaults menu
PIN of Day Key
The PIN of the day option can be enabled/disabled by the engineer. When this option is on
(key not zero) the engineer PIN code will be changed every day at midnight. The sequence of
PIN codes generated will depend on the programmed key. Each key has a corresponding 4
digit seed number which is never displayed on the keypad. The PIN code for each day can
only be obtained by programming the 4 digit seed number into the PIN of the day PC program.
If the PIN of the day option is on when power is applied Windsor will set the date to Monday
7th September 1992 and the engineer PIN code will be set to the default PIN for that day.
PIN of Day Key
0
0-9
If you intend to use PIN of the day you must be allocated a key number and the
corresponding seed number by Guardall.
Edit page 1
System Size
The system size should be the first item programmed. To view or modify the system size
options select option 1 from page 1 of the edit menus.
Areas-2
There are 3 system size menu options.
Conc-02
Keypad-2
System Size
Areas-2
1-7
The area system size can be specified in the range 1-7. When the number of areas is
programmed all area menus (for example when setting) will be limited to the specified area
system size.
System Size
Conc-02
01-16
The concentrator system size can be specified in the range 01-16. When the number of
concentrators is set the maximum circuit value is set to 8 times the specified concentrator
system size. The concentrators must be addressed from 1 up to the concentrator
system size limit.
System Size
Keypads-2
1-8
The keypad system size can be specified in the range 1-8. This value excludes the engineer
keypad (keypad 0). The keypads must be addressed from 1 up to the keypad system size
limit. If a keypad stops replying Windsor will report a keypad communications failure.
When the system size has been set the system can be checked using the engineer check
mode. Check mode will report the number of keypads and concentrators actually replying.