Windsor 500 Programming Manual - Issue C
- 67 -
If you do not want dual reports program off.
Dual Alm.Rpt. menu
Backup
If dual alarm reporting as a backup is enabled then Windsor will always send a dual alarm
report. If backup is off then a dual report is only sent if Windsor fails to communicate with the
primary alarm communicator number and, if programmed, the secondary alarm communicator
number.
Alarm comm menu
Restore
This is an ADEMCO reporting option and is useable with SmartDial and SmartComm. Each of
the 8 device channels can be programmed for restore. If the programmed channel status
changes from alarm to clear then an ADEMCO restore code will be transmitted.
Restore
1-Off
Off/On
. . .
8-Off
Off/On
Alarm comm menu
Open/Close
This is an ADEMCO reporting option and is useable with SmartDial and SmartComm. Each of
the 8 device channels can be programmed for open/close. If the programmed channel status
is alarm a close code will be reported. If the programmed channel status is clear an open
code will be reported. The restore option will be ignored if it is programmed for a channel with
open/close also programmed.
Alarm comm menu
Alarm Rpt.
The engineer can select which categories of data to report to the Guardall Configuration
Manager (GCM), MAS, a mimic panel and a point ID receiver. The report categories are
alarms (this will include circuits and system alarms), set/unset, bypass, trouble, log on,
engineer on, reset and circuit alarm restores.
Alarm Rpt
Alarm-Off
On/Off
Set/Uns-Off
On/Off
Bypass-Off
On/Off
Trouble-Off
On/Off
Log On-Off
On/Off
Eng On-Off
On/Off
Reset-Off
On/Off
Restore-Off
On/Off
The report categories will apply to all telephone numbers programmed to use the Guardall
format or point ID and to all mimic data. There is a table showing all reported point ID codes
and a table showing all events by alarm category in the following section.
Individual TX/Device options do not need to be programmed in order to send data in
the above formats. However, it is still possible to program a TX channel for a circuit or
area event and activate a different communicator and/or a local indication from a
single alarm event.