Windsor 500 Programming Manual - Issue C
- 72 -
Comms menu
Eng Comm
An engineering communicator can be connected on the Serial or Printer ports (v3.00 only) .
There is a choice of serial port devices (see hardware/serial port). The printer port device is
always a PC. The engineering communicator can be used for all downloading operations.
0=Type
There are 6 eng comm menu options.
1=Eng Num
2=Operations
3=Ring Count
4=Dble Call
5=Auth. Code
Eng comms menu
Type
0=Off
1=Serial Port
2=SmartDial
3=Printer Port
New in v3.00
If you do not use an engineering communicator program the type as off.
Eng comms menu
Eng Num
This number will only be used by Windsor if call back is configured. Windsor will use the
normal 3 attempt call pattern (6 when using PAKNET) when connecting to the engineering
telephone number.
Eng Num
0-16 digits
Eng comm menu
Operations
All remote operations must be individually programmed. The programmable operations can be
viewed/modified by selecting 2 from the engineering communicator menu.
Operations
Enable-Off
Off/User/Auto.
Call Back-Off
Off/On/RPS.
Reset-Off
Off/Unset.
Unset-Off
On/Off.
PIN-Off
Off/Unset.
Clock-Off
Off/Unset/SetUns.
Bypass-Off
Off/Unset/SetUns.
Soak-Off
Off/Unset.
Log-Off
Off/Unset/SetUns.
ConfigRD-Off
Off/Unset/SetUns.
ConfigWR-Off
Off/Unset/SetUns.
The options for each remote operation comply with the BSIA downloading guidelines.