Windsor 500 Programming Manual - Issue C
- 58 -
Edit page 2
Sounder
Windsor has a number of sounder options for each individual area. To view or modify the
sounder options select option 6 from page 2 of the edit menus.
Time-10
Delay-Off
Standby-Off
Ent Alm-Off
Pre-Warning-On
System Set- Off
New in v3.00
P.Set Delay-On
New in v3.00
Sounder menu
Time
Sounder Area-n
Time-10
0-30 minutes
Windsor has a sounder relay on the main PCB and each area may have a programmable
sounder TX output (see comms/TX/area). This TX output will be on when the main PCB
sounder is on. The sounder output(s) is always turned off at the end of the programmed
sounder duration. If a time of 0 is programmed then the sounder will remain on until manually
reset.
If an alarm event is considered to be in more than one area (for example a tamper or system
entry alarm) then all area sounders will be turned on. Each area sounder will be timed
independently and the main PCB sounder relay will only be turned off when the last timed area
has been turned off.
Not all alarm events will trigger the sounder. For further details check the circuit and system
alarm event response tables.
Sounder menu
Delay
Sounder Area-n
Delay-00
0-30 minutes
Windsor can be programmed with a timed delay for each area. In this case the sounder, audio,
UI Bleeper(s) and any programmed light zones outputs will not be activated until after the delay
duration. This option should only be used when the alarm event is triggering a communicator.
Windsor will ignore the programmed delay if there is a line fault present, the communicator
makes 3 unsuccessful attempts to send an alarm report or if Home Set applies. To turn off this
feature enter a time of 0.
The sounder delay only applies to NA, ER and 24Hr (when set only) circuit types and all
tamper types when set.
Sounder menu
Standby
Sounder Area-n
Standby-Off
On/Off
Windsor can be programmed to operate in standby mode in the event of an alarm. If standby is
programmed the sounder will only be turned on if there is a line fault or if the communicator
makes 3 unsuccessful attempts to send an alarm report. This option should only be used when
the alarm event is triggering a communicator. Windsor will still time the alarm for the