Windsor 500 Programming Manual - Issue C
- 36 -
Cct Type
Exc-D
An Exc-D (Excalibur daylight) circuit is not in any area. The action of an Excalibur daylight
type input is to arm all Excalibur trigger inputs in the programmed zone when the input
voltage falls below the programmed level. The programmable range is 1-64 which
corresponds to a voltage range of 0-V max. (see Lights section for more details). If dusk
mode is programmed the programmed zone output will also be turned on when the dusk
threshold is reached. Only one Excalibur daylight type should be programmed for each of the
4 zones.
Exc-D
Help menu
Level-20
0-63
Light Zone-1
1-4
Slave Cct-0
0-max ccts
Cct Type
Exc-T
An Exc-T (Excalibur trigger) circuit is not in any area. Excalibur triggers are only armed when
the programmed light zone is in night mode or when the light zone is being tested. The
action of an Excalibur trigger alarm is to turn on the programmed zone output for the
programmed auto time (see Lights section for more details).
Exc-T
Help menu
Light Zone-1
1-4
Slave Cct-0
0-max ccts