Windsor 500 Programming Manual - Issue C
- 106 -
Change History
Issue C
Software Version 3.00
1. Corrected Plug-on comm section for PC820 (Windsor mark 2). Added typical channel
assignments and new channel 8 option.
2. Added Windsor modem to serial port devices. Changed modem description to Hayes
modem.
3. Added Pacom to serial port devices (was in UK version but not documented).
4. Added start time for event programmer schedule (operate through midnight).
5. Option to allow a manager user to change the event programmer times.
6. Option to allow only a manager user to unset if auto unset 1 or 2 is configured.
7. Added Unset 2 time in the event programmer. Changed Unset prompt to Unset 1.
8. All circuit shunt operations are now recorded in the event log.
9. Changed the vault timer to a programmable time. Modified operation so that the vault timer
cannot be the first area to be unset.
10. Added communicator ID codes for each area.
11. Added programmable line fault response (audible and delay time)
12. Added Comms OK output.
13. Removed Primary and secondary options from the alarm comm menu and added a
numbers option.
14. Removed Tel Number option from the main comms menu.
15. Added a method of erasing a telephone number.
16. Added set, unset and toggle options to key circuits.
17. Circuits in multiple areas.
18. Bypass groups increased from 4 to 6.
19. Added auxiliary technical alarm option for signalling in PS/2 and point ID.
20. Added use dual telephone number for Aux circuit types.
21. Option to log circuit alarms in the display and event logs for all circuits with a log response.
22. Unset delay option for circuits with an alarm response.
23. Removed shunt 24 and Aux 24 circuit types. Shunt and Aux now have set/unset options.
24. The printer port now has a PC option. Menu option changed from Printer to Printer port.
25. Added printer port as eng comm type.
26. Added audible warning (TX Rst Warn) for engineer reset if ACPO TX reset is programmed.
27. Added part set sounders option.
28. Added an audible mains fail programming option.
29. Added one unset per day option for users.
30. Added time schedules to user menu and time schedules menu option.
31. Added slave circuit option to all circuits.
32. Added common area programmable set mode.
33. Added engineer log on without user code option.
34. Reduced the size of the telephone number ID codes from 8 to 4 digits.
35. Added a timed TX output for each keypad when a user logs on.
36. Added duress PIN enable.
37. Added a tamper engineer reset option.
38. User clock change disable.
39. The site ID has been increased from 6 to 8 digits.
40. Added support for the AV60 (ISB & microphone/area menu)
41. No bell delay when part set option.
42. Home set now only applies to the communicator.
43. Added blind dial and recall comms options.
44. The method of programming the restore and open/close channels has been modified.
45. Temp bypass option removed. There is now a temp bypass option for individual
bypassable circuits. The temp bypass programming option now applies when setting with a
key circuit or using the event programmer.
46. EnEx SysSetUns option changed to apply when more than 1 area is programmed.
47. Removed the key holder option.
48. Increased number of users from 40 to 50.
49. Re-organised the TX functions. Removed the watchdog and STU acknowledge outputs.
Swapped position of Verify and Daily TX options.
50. Added the alarm abort option.
51. Noted that area IDs must be 4 digits.
Содержание Windsor 500
Страница 1: ...Windsor 500 Programming Manual Issue C ...
Страница 39: ...Windsor 500 Programming Manual Issue C 39 Log On On Off ...
Страница 54: ...Windsor 500 Programming Manual Issue C 54 TX Reset Normal Help Menu ...
Страница 108: ...Guardall Limited Lochend Industrial Estate Newbridge Edinburgh EH28 8PL Scotland Part No 320488 Issue C ...