Windsor 500 Programming Manual - Issue C
- 35 -
Cct Type
PA or PA-Snd
There are two types of PA response programmable, PA which is silent and PA-Snd which
gives an audible response. Windsor can also be programmed with duress codes (see user
authority) and each keypad can be programmed for dual key PA functions (see keypad
programming).
PA & PA-Snd Response
Active when
when set and unset.
Response
Sounder, Strobe (when set), audio (PA-Snd only). TX set and unset
Log Message
PA Alarm
Special conditions
PA engineer reset, slave circuit, unset delay (PA-Snd only), dual.
PA
Help menu
Area 1-Off
On/Off
. . .
Area 7-Off
On/Off
TX-0
0-8
Dev-01
00-19
Slave Cct-0
0-max ccts
Dual-Off
On/Off
Unset Delay-Off
On/Off
Cct Type
Fire
Fire circuits can be powered from a programmed power reset output (see comms/TX). When a
fire circuit alarm is reset power will be removed from the fire circuits. Windsor keypads can be
programmed for a dual key Fire alarm (see keypad programming). Windsor can be
programmed to auto reset fire circuits (see reset). The fire alarm audio tone is unique.
Fire Response
Active when
when set and unset.
Response
Sounder, Strobe, audio and TX when set and unset.
Log Message
Fire
Special conditions
Auto reset (if programmed) dormitory (if programmed), slave circuit,
unset delay, dual.
Fire
Help menu
Area 1-Off
On/Off
. . .
Area 7-Off
On/Off
TX-0
0-8
Dev-01
00-19
Dorm-0
0-2
Slave Cct-0
0-max ccts
Dual-Off
On/Off
Unset Delay-Off
On/Off