Windsor 500 Programming Manual - Issue C
- 31 -
Address Selection
Each of the concentrator variants uses a different method of address setting.
Address Selection
Address
(Windsor Numbering)
Vigil Mk2
DIL Switches
5 4 3 2 1 0
Sovereign
Diodes
D2 D6 D5 D4
Windsor
Links
LK1 LK2 LK3
Concentrator 1
0 0 0 0 0 0
x x x x
x x x
Concentrator 2
0 0 0 0 1 0
x x / x
x x /
Concentrator 3
0 0 0 1 0 0
x / x x
x / x
Concentrator 4
0 0 0 1 1 0
x / / x
x / /
Concentrator 5
0 0 1 0 0 0
/ x x x
/ x x
Concentrator 6
0 0 1 0 1 0
/ x / x
/ x /
Concentrator 7
0 0 1 1 0 0
/ / x x
/ / x
Concentrator 8
0 0 1 1 1 0
/ / / x
/ / /
Concentrator 9
0 1 0 0 0 0
Concentrator 10
0 1 0 0 1 0
Concentrator 11
0 1 0 1 0 0
Concentrator 12
0 1 0 1 1 0
Concentrator 13
0 1 1 0 0 0
Concentrator 14
0 1 1 0 1 0
Concentrator 15
0 1 1 1 0 0
Concentrator 16
0 1 1 1 1 0
x = diode cut or link not fitted
/ = diode not cut or link fitted
If your Windsor system has more than 8 concentrators then you must use a Vigil Mk2 or
internal concentrator (maximum of 3) for concentrators addressed as 9 to 16. Any
combination of concentrator types is allowed in a system.