Windsor 500 Programming Manual - Issue C
- 30 -
for any number of concentrators. If output 3 is programmed for any other function then the
device number is the concentrator number to be used for the circuit data. For example if
concentrator 1 output 3 is programmed for the Cct Status of device number 8 then the
concentrator 1 daughter board outputs will follow the status of circuits 56-64 (the concentrator
8 inputs). The programmed device number for an output programmed for a circuit
function should not be greater than the maximum number of concentrators in the
system.
Concentrator Variants
Although any type of Guardall concentrator may be used with Windsor there are some
important differences between the different concentrator variants. The main differences are
outlined in the following tables.
Variant
Method of selecting the address
Windsor
Shunt Links
Vigil Mk2
DIL Switch
Sovereign/Vigil Mk1
Cutable diode links
Internal
Programmed from a keypad
Concentrator Addressing
Windsor Address
Sovereign Address
Vigil Address
1
On Board
1
2
1
3
3
3
5
4
5
7
5
7
9
6
9
11
7
11
13
8
13
15
9
not available
17
10
not available
19
11
not available
21
12
not available
23
13
not available
25
14
not available
27
15
not available
29
16
not available
31
Concentrator Output 1 & 2 References
Windsor
Sovereign
Vigil
O/P1
PL10
PL10
O/P2
PL11
PL11
not available
PL9
PL9