Windsor 500 Programming Manual - Issue C
- 80 -
Area TX Function
A.Set Flt
This output will be turned on if the area is being auto set with faults present or if the area
cannot auto set. It will be turned off when the area is unset, reset or set.
Area TX Function
Shnt Flt
This output will be turned on if a circuit is in alarm when the shunt is removed. It will be turned
off when the circuit is clear.
Area TX Function
Set Warning
This output will be turned on during the event programmer set warning period.
Area TX Function
EVP Open
This output will be turned on during the event programmer open close time window.
Area TX Function
Ready
This output will be turned on if the programmed area is ready to set (all NA type circuits are
clear).
Area TX Function
Set Alm
This output will be turned on if any NA, ER or 24Hr type circuit or an entry alarm occurs when
the programmed area is set. It will be turned off when a user resets.
Area TX Function
Unset Alm
This output will be turned on if any 24Hr type circuit alarms when the programmed area is
unset. It will be turned off when a user resets.
Area TX Function
Sounder
This output will be turned on if there is any sounder activity in the programmed area. This
output is in addition to the main PCB sounder output.
Area TX Function
Audio
This output will be turned on if there is any audio activity in the programmed area. This output
is in addition to the main PCB audio output.
Area TX Function
Strobe
This output will be turned on if there is any strobe activity in the programmed area. This output
is in addition to the main PCB strobe output.