Windsor 500 Programming Manual - Issue C
- 42 -
When setting using EnEx or EnEx/Timed modes setting will be completed by a EnEx circuit
under the following conditions;
1. If Sys Set/Uns is on and ;
•
the system is being set
•
all unset areas are being set
2. If Sys Set/Unset is off and;
•
the programmed EnEx area is being set.
•
the EnEx circuit is programmed for 1 area and the system is being set.
•
the EnEx circuit is programmed for all areas and any area is being set.
When unsetting the following conditions apply;
1. If Sys Set/Uns is on;
•
Windsor will ignore the EnEx circuit unless all programmed areas are set.
2. If Sys Set/Unset is off;
•
Windsor will start unsetting all EnEx circuit areas which are set.
Cct Options
Auto Check
This option applies to NA and ER circuit types only. If a circuit is programmed for auto check
then, when the circuit is unset, Windsor will expect the circuit to alarm at least once during the
programmed auto check period prior to setting (See Set/Uns Opts/Auto check). If a circuit fails
to alarm during this time then the circuit cannot be set. Setting can only proceed after the
circuit has been successfully tested. Circuits which are bypassed or isolated do not need to be
tested.
All of the following options are new in v3.00.
Cct Options
Set Flt
A key circuit can be programmed to set with faults. Any circuit in the area(s) being set which is
in alarm and is programmed for temp bypass will be temporarily bypassed.
Cct Options
Slave Cct
Any type of circuit can have the slave circuit option programmed. When a circuit with the slave
circuit programmed alarms the alarm response will be the combined response of the
programmed circuit and it’s slave circuit number. Program 0 to disable a slave circuit
response. More than one slave circuit response can be obtained by linking together slave
circuits but there must be at least one circuit which is not a slave circuit.
Cct Options
Set
When this option is applied to a key type circuit then Windsor will attempt to set the
programmed area when the circuit alarms.
If this option is applied to a other types of circuit then the circuit will have a set response.