Windsor 500 Programming Manual - Issue C
- 65 -
1=Tel Num
A 16 digit number including pause digits.
2=ID
4 digit IDs for each area.
3=Format
The communication format.
4=Auto Test
Select on to make a automatic test calls to this number.
Numbers menu
Tel Num
A telephone number of up to 16 digits can be programmed. This number can include pause
digits. Pause digits can be entered using the
↑
button. This will be displayed as a “,” character.
Each pause digit represents a 1 second delay. Pauses may be required if you are signalling
via a PABX or if the call is routed through an old exchange.
Primary
0-16 digits
To erase a telephone number press the
↓
button (v3.00 only).
When reporting an alarm Windsor will make up to 3 dial attempts (6 attempts using PAKNET)
to the primary number (see Call Pattern). If Windsor fails to connect to the primary number it
will call the secondary number (if programmed). When reporting an alarm Windsor will make
up to 3 dial attempts (6 attempts using PAKNET) to the secondary number.
Numbers menu
ID
Each area (v3.00 only) can be programmed with a unique 4 digit ID
17
.
0=System
1=Area 1
. . .
2=Area 7
Select the area number to be programmed.
Primary ID n
0-max areas
nnnn
4 digits
To erase an ID number press the button. If an area does not have a unique ID programmed
Windsor will report all such area events using the system ID number. The system ID number
is also used when reporting system events such as a panel tamper. If the ID number is less
than 4 digits leading zeros must be entered. If a circuit is programmed in more than 1
area the system ID will be used in all alarm reports.
If the Guardall format is being used to send alarms to GSR (GuardStation Remote) it is not
necessary to program any Site IDs. If a System ID
18
is programmed Windsor will use this in
place of the Site ID. The area IDs are never used in GSR communications.
17
Area IDs can only be used with the Windsor modem or SmartDial Super v2.8 or later and the Contact
ID format.
18
GSR will identify the System ID as a different customer and there must be a corresponding entry in
the customer database.