Windsor 500 Programming Manual - Issue C
- 10 -
Windsor Editor
Help List
Configuration items such as circuit type require a type to be entered. This can be entered
directly as a number or, if the HELP button is pressed, a list of available options will be
displayed.
0=Off
1=NA
2=ER
3=EnEx
4=PB
5=24h
6=PA
7=Fire
8=Exc-D
9=Exc-T
↵
=Next Page
Windsor Editor
On/Off Options
Some programming items are simple on/off options. You can either enter “0” for off or “1” for
on or if you press HELP the on/off options will be displayed.
0=Off 1=On
the help display for an on/off programming field
Windsor Editor
Text Descriptions
Text descriptions can be entered for some programming options, e.g. circuits. Text can be
entered by using the
↑
and
↓
buttons to select the required character from the alphabet.
Cct Number 1
the item being programmed
Cct 01
the current descriptor
Windsor Editor
Range Checking
Range checking is done when a number is entered. If a range error is detected, then the
programming limits will be displayed.
Out of Range
Limit=1 to 16