Troubleshooting
3500/42 Operation and Maintenance
196
I/O Module Compatible
Event Number: 63
Event Classification: Severe / Fatal Event
Action: Verify that the type of I/O module installed matches what was selected
in the software. If the correct I/O module is installed, there may be a
fault with the Monitor Module or the Monitor I/O module.
* Fail I/O Jumper Check
Event Number: 64
Event Classification: Severe / Fatal Event
Action: Verify that the type of I/O module installed matches what was selected
in the software. If the correct I/O module is installed, there may be a
fault with the Monitor Module or the Monitor I/O module.
Monitor Module will stop alarming.
Pass I/O Jumper Check
Event Number: 65
Event Classification: Severe / Fatal Event
Action: Verify that the type of I/O module installed matches what was selected
in the software. If the correct I/O module is installed, there may be a
fault with the Monitor Module or the Monitor I/O module.
Fail Main Board +5V-A
(Fail Main Board +5V - upper Power Supply)
Event Number: 100
Event Classification: Potential Problem
Action: Verify that noise from the power source is not causing the problem. If
the problem is not caused by noise, check to see if one of the following
components is faulty:
- the Monitor Module
- the Power Supply installed in the upper slot
Pass Main Board +5V-A
(Pass Main Board +5V - upper Power Supply)
Event Number: 101
Event Classification: Potential Problem
Action: Verify that noise from the power source is not causing the problem. If
the problem is not caused by noise, check to see if one of the following
components is faulty:
- the Monitor Module
- the Power Supply installed in the upper slot
Fail Main Board +5V-B
(Fail Main Board +5V - lower Power Supply)
Event Number: 102
Event Classification: Potential Problem
Action: Verify that noise from the power source is not causing the problem. If
the problem is not caused by noise, check to see if one of the following
components is faulty:
- the Monitor Module
- the Power Supply installed in the lower slot