SIGNAL CONDITIONING
Specified at +25
°
C (77
°
F)
Radial Vibration
Frequency Response:
Direct Filter:
Gap Filter:
*Not 1X Filter:
*Smax:
*,**1X & 2X Vector Filter:
User-programmable for 4 to 4,000 Hz or 1
to 600 Hz.
-3 dB at .09 Hz.
60 cpm to 16 times running speed.
Constant Q notch filter. Minimum rejection
in stopband of –34.9 dB.
0.125 to 16 times running speed.
Constant Q Filter. Minimum rejection in
stopband of -57.7 dB.
* Note - 1X & 2X Vector, Not 1X, and Smax parameters are valid for
machine speeds of 60 to 60,000 cpm.
**Note - Minimum Signal Amplitude for Phase measurement is 42.7 mV
Accuracy:
Direct and Gap:
1X & 2X:
Smax:
Not 1X:
Within
±
0.33 % of full scale typical,
±
1 %
maximum.
Within
±
0.33 % of full scale typical,
±
1 %
maximum.
Within
±
5 % maximum.
±
3 % for machine speeds less than 30,000
cpm.
±
8.5 % for machine speeds greater
than 30,000 cpm.
Thrust and Differential Expansion:
Frequency Response:
Direct Filter:
Gap Filter:
Accuracy:
-3 dB at 1.2 Hz.
-3 dB at 0.41 Hz.
Within
±
0.33 % of full scale typical,
±
1 %
maximum.