Configuration Information
3500/42 Operation and Maintenance
68
The following table lists the Alert/Alarm 1 and Danger/Alarm 2 setpoints available
for each channel pair type. The setpoint number is used in the Communication
Gateway and Display Interface Modules.
Setpoint
Number
Radial Vibration
Thrust Position
Differential
Expansion
1
Over Direct
Over Direct
Over Direct
2
Over Gap
Under Direct
Under Direct
3
Under Gap
Over Gap
Over Gap
4
Over 1X Ampl
Under Gap
Under Gap
5
Under 1X Ampl
Danger (configurable)
Danger
(configurable)
6
Over 1X Phase Lag
Danger (configurable)
Danger
(configurable)
7
Under 1X Phase Lag
Danger (configurable)
Danger
(configurable)
8
Over 2X Ampl
Danger (configurable)
Danger
(configurable)
9
Under 2X Ampl
10
Over 2X Phase Lag
11
Under 2X Phase Lag
12
Over Not 1X Ampl
13
Over S
max
Ampl
14
Danger (configurable)
15
Danger (configurable)
16
Danger (configurable)
17
Danger (configurable)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com