Configuration Information
3500/42 Operation and Maintenance
60
Slot
The location of the monitor in the 3500 rack (2 through 15).
Rack Type
Identifies the type of Rack Interface Module installed in the rack (Standard or
TMR).
Channel Frequency Support
Supported frequency range of the selected transducer which depends upon the
number of channels selected. See 3.1.7.1 (Velocity Channel Configuration
Considerations).
Enable
Direct
The time rate of change of the displacement. When Integration is selected it
yields a peak to peak measurement of the displacement.
The Direct values are available for all transducer types.
Direct
0-0.5 in/s pk
0-1 in/s pk
0-2 in/s pk
0 - 0.5 in/s rms
0-1 in/s rms
0-2 in/s rms
0-10 mm/s pk
0-20 mm/s pk
0-50 mm/s pk
0-10 mm/s rms
0-20 mm/s rms
0-50 mm/s rms
Custom
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com