Maintenance
3500/42 Operation and Maintenance
124
Radial Vibration Default OK Limits Table
Transducer
Lower OK Limit (volts)
Upper OK Limit
(volts)
7200 5&8 mm w/
barriers
-2.7 to -2.8
-16.7 to -16.8
7200 5&8 mm w/o
barriers
-2.7 to -2.8
-16.7 to -16.8
7200 11 mm w/o
barriers
-3.5 to -3.6
-19.6 to -19.7
7200 14 mm w/o
barriers
-2.7 to -2.8
-16.7 to -16.8
3300 5&8 mm w/
barriers
-2.7 to -2.8
-16.7 to -16.8
3300 5&8 mm w/o
barriers
-2.7 to -2.8
-16.7 to -16.8
3000 (-18 V) w/o
barriers
-2.4 to -2.5
-12.0 to -12.1
3000 (-24 V) w/o
barriers
-3.2 to -3.3
-15.7 to -15.8
3300 RAM w/o barriers
-2.4 to -2.5
-12.5 to -12.6
3300 RAM w/ barriers
-2.4 to -2.5
-12.1 to -12.2
3300 16 mm HTPS w/o
barriers
-2.7 to -2.8
-16.7 to -16.8
Note: Assume ±50 mV accuracy for check tolerance.