Configuration Information
3500/42 Operation and Maintenance
48
may be configured as Acceleration and Channels 3 and 4 may be configured
as Radial Vibration).
- When a full-scale range is modified, the setpoints associated with this
proportional value should be readjusted.
- If a Non-Standard transducer is selected, the setpoint OK limits are set to ±1
volt from the Upper and Lower OK limits that are selected.
- When integration is selected, the available Direct Full-scale ranges will change
to reflect this.
- When band-pass filtering is selected, the high-pass and low-pass filters must be
set a minimum of two octaves apart.
- When two channels of acceleration are activated, the maximum channel
frequency supported is as shown:
Dual Channel
Configuration Settings**
Frequencies
Filtering
RMS
Integration
3 to 30 kHz
No
No
No
10 to 30 kHz
No
Yes
No
3 to 9115 Hz
Yes
No
No
10 to 9115 Hz
---
---
Yes
10 to 9115 Hz
Yes
Yes
No
** Three dashes represent both yes and no
- When a single channel of acceleration is activated, the maximum channel
frequency supported is as shown:
Single Channel
Configuration Settings**
Frequencies
Filtering
RMS
Integration
3 to 30 kHz
---
No
No
10 to 30 kHz
---
Yes
No
3 to 9115 Hz
---
---
Yes
** Three dashes represent both yes and no
- The Latching OK Mode and the Timed OK Channel Defeat options are not
compatible.
- Internal Barrier I/O Modules and External Barriers are not supported with high
frequency accelerometer transducers.
- Only 18 high frequency accelerometer transducers can be installed along with a
full rack of standard transducers. This is due to the fact that the rack can
only power 18 high frequency Accelerometer transducers.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com