User's Manual
1208
Document #: LTRT-10375
Mediant 500 MSBR
Broken Connection
Timeout
configure voip > sip-
definition settings >
broken-connection-
event-timeout
[BrokenConnectionEvent
Timeout]
Defines the timeout interval (in 100-msec units) after which a call is
disconnected if RTP packets are not received during an established call
(i.e., RTP flow suddenly stops during the call).
The valid range is from 3 (i.e., 300 msec) to approx. 2684354 (i.e., 74.5
hours). The default is 100 (i.e., 10,000 msec or 10 seconds).
Note:
The parameter is applicable only if the
DisconnectOnBrokenConnection parameter is configured to 1.
Currently, the feature functions only if Silence Suppression is
disabled.
configure voip >
sbc settings > no-
rtp-detection-
timeout
[NoRTPDetectionTimeou
t]
Defines the timeout interval (in msec) after which a call is disconnected
if RTP packets are not received. The timer begins from call setup and if
no packets have been received when the timer expires, the device
disconnects the call.
The valid range is 0-50000. The default is 0 (i.e., disconnects the call
immediately).
Note:
If a call is established and RTP flow occurs, if at any stage during
the call RTP packets are not detected for a user-defined interval
(configured by BrokenConnectionEventTimeout), the device
disconnects the call (or routes it to an alternative destination, configured
by the IpProfile_DisconnectOnBrokenConnection).
Disconnect Call on
Silence Detection
configure voip > sip-
definition settings > disc-
on-silence-det
[EnableSilenceDisconne
ct]
Determines whether calls are disconnected after detection of silence.
[1] Yes = The device disconnects calls in which silence occurs (in
both call directions) for more than a user-defined time.
[0] No = (Default) Call is not disconnected when silence is detected.
The silence duration can be configured by the
FarEndDisconnectSilencePeriod parameter (default 120).
Note:
The parameter is applicable only to the Gateway application.
To activate the feature, enable Silence Suppression for the used
coder and configure the parameter FarEndDisconnectSilenceMethod
to 1.
Silence Detection Period
[FarEndDisconnectSilenc
ePeriod]
Defines the duration of the silence period (in seconds) after which the
call is disconnected.
The range is 10 to 28,800 (i.e., 8 hours). The default is 120 seconds.
Note:
The parameter is applicable only to the Gateway application.
For the parameter to take effect, a device reset is required.
Silence Detection
Method
[FarEndDisconnectSilenc
eMethod]
Determines the silence detection method.
[0] None = Silence detection option is disabled.
[1] Packets Count = According to packet count.
Note:
The parameter is applicable only to the Gateway application.
For the parameter to take effect, a device reset is required.
Содержание Mediant 500 MSBR
Страница 1: ...User s Manual AudioCodes Family of Multi Service Business Routers MSBR Mediant 500 MSBR Version 7 2 ...
Страница 2: ......
Страница 33: ...Part I Getting Started with Initial Connectivity ...
Страница 34: ......
Страница 36: ...User s Manual 36 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 40: ...User s Manual 40 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 45: ...Part II Management Tools ...
Страница 46: ......
Страница 48: ...User s Manual 48 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 115: ...Part III General System Settings ...
Страница 116: ......
Страница 132: ...User s Manual 132 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 137: ...Part IV General VoIP Configuration ...
Страница 138: ......
Страница 290: ...User s Manual 290 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 306: ...User s Manual 306 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 380: ...User s Manual 380 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 454: ...User s Manual 454 Document LTRT 10375 Mediant 500 MSBR This page is intentionallty left blank ...
Страница 455: ...Part V Gateway Application ...
Страница 456: ......
Страница 458: ...User s Manual 458 Document LTRT 10375 Mediant 500 MSBR IP to Tel Call Figure 24 1 IP to Tel Call Processing Flowchart ...
Страница 460: ...User s Manual 460 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 484: ...User s Manual 484 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 494: ...User s Manual 494 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 625: ...Part VI Session Border Controller Application ...
Страница 626: ......
Страница 654: ...User s Manual 654 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 656: ...User s Manual 656 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 741: ...Part VII Cloud Resilience Package ...
Страница 742: ......
Страница 751: ...Part VIII Data Router Configuration ...
Страница 752: ......
Страница 753: ......
Страница 754: ......
Страница 756: ...User s Manual 756 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 757: ...Part IX Maintenance ...
Страница 758: ......
Страница 834: ...User s Manual 834 Document LTRT 10375 Mediant 500 MSBR This page is intetnionaly left blank ...
Страница 837: ...Part X Status Performance Monitoring and Reporting ...
Страница 838: ......
Страница 848: ...User s Manual 848 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 852: ...User s Manual 852 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 854: ...User s Manual 854 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 878: ...User s Manual 878 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 880: ...User s Manual 880 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 926: ...User s Manual 926 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 927: ...Part XI Diagnostics ...
Страница 928: ......
Страница 950: ...User s Manual 950 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 954: ...User s Manual 954 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 956: ...User s Manual 956 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 958: ...User s Manual 958 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 974: ...User s Manual 974 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 976: ...User s Manual 976 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...
Страница 977: ...Part XII Appendix ...
Страница 978: ......
Страница 982: ...User s Manual 982 Document LTRT 10375 Mediant 500 MSBR This page is intentionally left blank ...